ADEMCO LYNXR Quick Start Manual - Page 4

Browse online or download pdf Quick Start Manual for Security System ADEMCO LYNXR. ADEMCO LYNXR 8 pages.
Also for ADEMCO LYNXR: Quick Start Manual (8 pages)

ADEMCO LYNXR Quick Start Manual
8.
Set RF House ID in the wireless keypads as follows:
If using a 5827 wireless keypad, set the keypad's DIP switches to the RF House ID programmed in
field *24. If using a 5804BD button key or 5827BD keypad, set the RF House ID per its instructions.
If using Powerline Carrier Devices, set their House ID to "A," (programmed as "0") or use field *25 to
change the ID to avoid conflicts with existing installations.
9.
Set the Real-Time Clock as follows:
Enter time/date setting mode by entering the Installer Code + [63].
The hour prompt is displayed. Enter the correct hour, then press [*] to accept and advance.
For each subsequent prompt, enter the correct value, then press [*].
You will exit this mode automatically after entering the year, or if no keys are pressed for 1 minute.
10. Test the system as follows:
After installation and programming, enter Installer Code + TEST.
To exit Test mode, enter Installer Code + OFF.
11. Assign desired User Codes by following the procedures on the next page and in the User Guide.
Show the user how to perform the various system functions.
12. Perform site-initiated downloader session (to load central station ID) by Installer Code + [#] + [1].
EARTH GROUND
WARNING:
TO PREVENT
RISK OF
SHOCK,
RJ11
POSITION
DISCONNECT
TELEPHONE
LINE AT TELCO
JACK BEFORE
SERVICING
TO HANDSET
INCOMING
PHONE
THIS UNIT.
LINE
ALL OUTPUT CIRCUITS
ARE POWER LIMITED.
LOCAL SOUNDER
DISABLE JUMPER
CUT = DISABLE
THIS EQUIPMENT SHOULD BE INSTALLED
IN ACCORDANCE WITH THE NATIONAL
FIRE PROTECTION ASSOCIATION'S STAN-
DARD 72, CHAPTER 2 (NATIONAL FIRE
PROTECTION ASSOC., BATTERYMARCH
PARK, QUINCY, MA 02269). PRINTED
INFORMATION
DESCRIBING
PROPER
INSTALLATION, OPERATION, TESTING,
MAINTENANCE, EVACUATION PLANNING
AND REPAIR SERVICE IS TO BE PROVIDED
WITH THIS EQUIPMENT.
THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY
INTERFERENCE RECEIVED, INCLUDING INTERFERENCE
THAT MAY CAUSE UNDESIRED OPERATION.
PHONE
ZONE
8
2
3
5
6
1
4
JACK
TIP
RING
TIP
RING (+)
HARD
WIRED
PHONE
ZONE
LINE
EARTH
INCOMING
HANDSET
PHONE
GROUND
PHONE
LINE
LINE
2k OHMS
EOLR
WEEKLY TESTING IS
REQUIRED TO ENSURE
PROPER OPERATION
OF THIS SYSTEM.
FCC ID: CFS8DLLYNX
COMPLIES WITH FCC RULES, PART 68
FCC REGISTRATION No. 5GBUSA-25623-AL-E
RINGER EQUIVALENCE: 0.6B
LYNX WIRING CONNECTIONS
Page-4
LRR/AAV
TRIGGER
SOUNDERS PLCD
AC
8
9
12
7
10
11
13
14
15
( )
( )
(+)
( )
(+)
DATA
SYNC
OUT
IN
PIEZO
BELL
6-14VDC
6-14VDC
NOTE: LYNX REQUIRES A BACKUP BATTERY. USE
30mA max.
120mA max.
SIX 1.5V ALKALINE "AA" BATTERIES (DURACELL
(e.g., WAVE2EX)
MN1500 OR VARTA 4706 ONLY).
REPLACE BATTERIES AT LEAST EVERY YEAR.
LYNX-R IS EQUIPPED WITH AN INTEGRAL
RECHARGEABLE BATTERY PACK P/N LYNXRCHKIT.
REPLACE EVERY FOUR YEARS.
BLACK
YELLOW
RED
GREEN
4-WIRE MODULAR
PHONE CORD WITH
FLYING LEADS
16
PLUG-IN
TRANSFORMER
(e.g., ADEMCO 1332)
CANADA USE 1332CN
TO 24HR 110VAC
9VAC
UNSWITCHED
15VA
OUTLET
PL513
POWERLINE INTERFACE
1 2 3 4