ADEMCO Vista 4120 Installation Instructions Manual - Page 7
Browse online or download pdf Installation Instructions Manual for Security System ADEMCO Vista 4120. ADEMCO Vista 4120 18 pages.
MOUWTIWG THE LOCK
1. Remove the loch knockout on
the control cabinet cover.
Insert the key into the loch.
Positiin the kch in the hole
making certain that the latch
will make contact with the
latch bradset when the door is
2. While holding the bdc steady,
insert the retainer dip into the
retainer slots. Position ciii as
illustrated to facilitate easy
removal.
I)
1:
2:
6:
7:
xj
10:
11:
12:
'9
UNLOCKED
CLIP
CABINET DOOR BOTTOM
TERMINALS
AC Input from No. 132lITF2 plug-k transformer (16.5
VAlCAl!5;A).
In Canadian
installations,
use
AC Input from No. 132lITF2 plug-in transformer (16-s
VAC. 25VA). In Canadian installations,
use No.
1321cN.
Afarm relay output (+), 12 VDC, 28A maximum.
Alarm Oulput/Auxilii
Power (-) Return.
Continuous AuxiliasylRomote Console Power (RED):
+12VDcat700mA.
Console Data In (GREEN)t.
console Dataout (YELLOW)?
Remote Console Ground (-) (BLACK$.
Ground Start Output (to BLUE LEAD on No. 675
Ground Start Module). or Hiih Site of Zone 1 when
zone is usad as an End-of-Line Resistor supervised
burglary, panic or P-wire smoke detector compatibfe
fire zone. Terminal 12 would net be ueed for Zone 1
when this terminal is used for Zone 1.
Zone 1 Return when tine 1 is programmed (Field '41)
as an EOLR supervised zone, a 2,000 Ohm EOLR
should be wired between thii terminal and the hih
aide of the zone on Terminal 9. Zone 1' High Side
when used with terminal 12 wlthout EOLR.
zone 2'
Zones 1 and 2 Return (not wad for Zone 1 if EOLR
la used)
13: Zone3'
14: zonea*
AElAlNER CLIP
(NOTE POSITION)
RETAINER
SLOTS
17: ZoneV
18: Zones 5 and 6 Return.
19: zoner
20: zone 0'.
21: Zones 7 and 8 Return and EARTH GROUND (a proper
earth ground must be provided to protect the system
from llghtnlng and l lectroatatk discharge damage).
E .
241
Hz
Rpyl.
Irooming Phone Line (TfP).
25:
Incoming Phone Line (RING).
tHome run each consofe. Use no more than 220' of 1122 wire or
55Q of Xl 8 wire.
l
Zone that is programmable for use either as a N.C. sensor loop
or as a N.O. sensor loop (in Field -08). Zone response time
during digii communkation may be as bng as one second.
Warning: To prevent the risk of shock, disconnect telephone
line at kko jack More servicing the unit.
RED LEA& Battery (+) - When AC is present, 13.8 MC is being
developed to recharge a Starved Lead Acid or Gel battery and
when AC is absent, 12 VDC current is drawn from the battery.
Battery bad reversal damage protectkn is provided.
ElMIt
LUD: Battery (-).
15: Zones 3 and 4 Return.
16: Zone5