6.1.- Procedure for replacing cartridges and the membrane.
a. Close the water supply brass ball valve (Figure-5).
b. Open the faucet (figure 2) to relieve the pressure from inside the os-
mosis system.
c. To change any of the cartridges and/or membrane they must be
turned clock-wise and pulled downwards to remove it from its cap as
indicated in the follow-ing figure. This process must be carried out for
each of the cartridges that you want to replace.
d. Remove the cartridges/membrane from their original packaging.
Each car-tridge and/or membrane must be placed in the correspond-
ing position main-taining the correct order. To do so, you must insert
each cartridge in its cap and turn it anti-clockwise. This process must
be carried out for each of the car-tridges that you want to replace.
9
ref: MA-UF-0002-EN-V14.0-ATHENEA.pdf