Before undertaking any of the following task, please make sure that
the filtration unit is switched off and you are wearing the
appropriate safety equipment – Safety glasses and gloves
Emptying the Filter Socks
1. Switch off the filtration unit
2. Unscrew the blue filter collar from the main filtration unit (you may
need the wrench provided to loosen)
3. Empty excess water into the central filter
4. The solids should be at the bottom of the sock and can be emptied
into your solid waste
SLUDGE INTO THE CENTRAL CHAMBER
5. Check the fit of the sock and inner ring in the collar and adjust if
necessary. (you occasionally may need to clean the inner ring of
lens waste)
6. Reattach blue collar to the main filter using the wrench to ensure
that the pod is tight
7. Check operation to ensure no leaks between the top and bottom
halves of the blue collar and main unit
Safety Notice – Wear safety glasses when removing the socks
from the unit. When using the wrench make sure you wear the
gloves provided. Replacements or extra pairs are available from
Mainline Optical Connections.
If this task is not done on a daily basis the socks will continue to fill and
the emptying will become difficult, possibly leading to the socks being
damaged and affecting the performance of the filtration unit.