CHAPTER 6
SERVICING AND
MAINTENANCE
m
WARNING
© Airflow - we reserve the right to make changes without prior notice

Opening and closing the internal grille

5.1
The internal grille is fully open upon delivery (fig.13).
To close the internal grille, turn front cover two full turns clockwise until it "Clicks" into position (fig.14)
Internal grille in
open position
6.0

Servicing and maintenance

m
WARNING!
Touching live electrical parts will lead to electric shock.
Before any servicing and maintenance work, isolate the unit from the mains power supply and protect
against being switching on again!
m
WARNING!
The rotating impellers can be a hazard to fingers. Ensure all rotating parts have stopped.
– Excessive deposits of dirt, dust, grease, etc. on the impeller, motor, protection grille and, above all, between the
housing and impeller, are not permitted, as these can lead to an unbalance in the impeller, overheating of the motor
or the blocking of the impeller. In such cases, the unit must be cleaned.
– If the unit has not been used for long periods of time, maintenance must be carried out before the unit is restarted.
– If the unit has not been used in more than 2 years, the fan must be replaced.
Note the following:
• Remove deposits of dirt, e.g. on protection grille
• Conduct a visual inspection, replace damaged parts
• Freewheeling of the impeller, is impeller blocked, see Fault causes 6.3
• Vibrations – see Fault causes 6.3
• Fan unit must be inserted up to the "external grille" stop in the wall sleeve
6.1

Filter change

After the set time interval for the filter change, the upcoming filter change will be indicated on the controller by the
"
"flashing" LEDs. Proceed as follows:
1. Remove internal grille (fig.15).
2. Replace the Coarse 50% filter (fig.16)
Accessories: Set/2 pcs Coarse 50% filter, Part No: 90001014
3 . The internal grille is re-attached after the filter has been changed. Ensure that the internal grille is re-inserted with the
opening at the top .
4. Then hold down both buttons on the controller for longer than two seconds and confirm the filter change. This will
confirm the filter replacement process and reset the filter reminder.
Remove
internal grille
Unohab Cavity Wall Installation Kit
fig.13
fig.15
10
Installation and Operating Instructions
Close internal
grille by turning it
fig.14
"Click"
fig.16
Replace
Coarse 50%
filter