AEG TR8TRIER User Manual - Page 14

Browse online or download pdf User Manual for Dryer AEG TR8TRIER. AEG TR8TRIER 32 pages.

hours (in 10 min steps). When this option is
maximum, load indicator disappears.
The cycle lasts as long as set drying time
regardless of the size of a load and its
dryness.
TIME DRYING RECOMMENDATION
up 10 min
action of cool air only (no heater).
10 - 40
additional drying to improve dryness af‐
min
ter previous drying cycle.
full drying of the small laundry loads up
> 40 min
to 4 kg, well spun (>1200 rpm).
Droogtijd on Wol program
Option applicable to Wol program to adjust
final dryness level to more dry or less dry.
6.3 + Antikreuk
Extends up to 120 minutes the anti-crease
phase (30 minutes) at the end of the drying
cycle. After drying phase drum rotates from
time to time to prevent creases. Laundry can
be removed during the anti-crease phase.
6.4 Stil
The appliance operates with low noise
without effect on the drying quality. The
appliance operates slowly with longer cycle
time.
6.5 Opfrissen
To refresh clothes that were in storage.
Maximal load cannot exceed 1 kg.
6.6 Zoemer
The acoustic signal sounds at the following:
• cycle end
• start and end of crease guard phase
The acoustic signal is by default always on.
You can use this option to activate or
deactivate the sound.
14
ENGLISH
Zoemer option off:
1. Turn the dryer on.
2. Select 1 of the available programs.
3. Touch and hold down Opfrissen button by
around 3 seconds.
The symbol
appears on the display.
4. To activate the Zoemer, touch the above
button again until the symbol disappears.
6.7 Klaar Over
This option allows choosing the time at
which a programme should terminate.
Once activated the machine waits for the
right moment to begin the drying process.
Klaar Over time is the sum of stand by time
and drying time.
To set the Klaar Over option:
1. Set the drying programme and options.
2. Touch Klaar Over repeatedly until the
display shows the desired time within the
programme should end (e.g.
the programme has to finish within 12
hours.)
3. Touch the Start/Pauze button. The drum
starts rotating to perform the ProSense
estimation, if foreseen in the selected
programme.
4. The appliance starts the countdown to the
end of the programme and the
programme will start at the right moment
for ending.
if