Pre-Start Checklist
1. Check oil level. Add oil if low. Do not overfi ll.
2. Check fuel gauge (if equipped). If propane
tank is low, have it refi lled. Check fuel system
components and lines for leaks.
3. Check and clean cooling areas, air intake
areas and external surfaces of engine
(particularly after storage).
4. Check that air cleaner components and all
shrouds, equipment covers, and guards are
in place and securely fastened.
5. Check spark arrestor (if equipped).
Starting
Carbon Monoxide can cause
severe nausea, fainting or death.
Avoid inhaling exhaust fumes.
Engine exhaust gases contain poisonous
carbon monoxide. Carbon monoxide is
odorless, colorless, and can cause death if
inhaled.
Rotating Parts can cause severe
injury.
Stay away while engine is in
operation.
Keep hands, feet, hair, and clothing away
from all moving parts to prevent injury. Never
operate engine with covers, shrouds, or
guards removed.
NOTE: Do not crank engine continuously for
more than 10 seconds. Allow a 60
second cool down period between
starting attempts. Failure to follow
these guidelines can burn out starter
motor.
NOTE: Upon start-up, a metallic ticking may
occur. Run engine for 5 minutes. If
noise continues, run engine at mid
throttle for 20 minutes. If noise persists,
take engine to your local Kohler
authorized dealer.
1. Place throttle control midway between slow
and fast positions.
2. Slowly turn fuel valve on propane tank to full
open position.
3. Turn key switch to START position. Release
switch as soon as engine starts. If starter
does not turn engine over, shut off key switch
immediately. Do not make further attempts to
start engine until condition is corrected. Do
not jump start. See your Kohler authorized
dealer for trouble analysis.
4
WARNING
WARNING
KohlerEngines.com
Cold Weather Starting Hints
1. Use proper oil for temperature expected.
2. Disengage all possible external loads.
Stopping
1. If possible, remove load by disengaging all
PTO driven attachments.
2. Turn fuel valve to full closed position and
allow engine to continue running until it runs
out of fuel. Turn key switch to OFF position.
Angle of Operation
Refer to operating instructions of equipment
this engine powers. Do not operate this engine
exceeding maximum angle of operation; see
specifi cation table. Engine damage could result
from insuffi cient lubrication.
Engine Speed
NOTE: Do not tamper with governor setting to
increase maximum engine speed.
Overspeed is hazardous and will void
warranty.
24 590 35 Rev. B