Electrical connections and specifications
Explanation of the wires
Wires color
Function
Green
Signal Supply Line
Brown
Minus
White
Signal Return Line
Specification and Technical Data
Switching element
Switching voltage
Switching current
Standby current
Switching power
Open-time
Operating temperature
Protection class
Consumption type
Fluids
Flow range
Accuracy
Allowed pressure
Protection class
Signal output
Filter (mash size)
Temperature
Dimensions (l x h x w)
Weight
12
Remark
Signal is given when the contact closes. The external
device must bring the voltage, which will be redirected
over the "cable minus" to the external device.
Ground
Signal is given when the contact closes. The external
device must bring the voltage, which will be redirected
over the "cable minus" to the external device.
Reed switch with dry contact (inert gas)
Max. 48 VAC / VDC, Protection class III (SELV)
Max. 50 mA (Ri=47Ω / 0.5 W)
Not available (galvanic isolated)
Max. 2 W
50 % ±10 %
-20 °C to +80 °C
IP 66
Differential consumption measurement
Diesel fuel
10 l/h up to 200 l/h (short time 260 l/h)
Better than 1 %
16 bar (operation pressure is viscosity depending)
IP 66
80 pulse/liters
The same mash size like the vehicle needs, at least 0.100 mm
Operating temp.
-20 °C up to +80 °C
Storage temp.
-40 °C up to +125 °C
157 x 96 x 81 mm
1.6 kg
Functions scheme
Supply/Return Line
+/–
Ri 47 Ohm
+/–
5.65078.4
CONTOIL
DFM 8ECO
®