Error Messages
Message
Icon
"PUMP
Er01
ON"
flashing
N/A
Er02
N/A
Er03
Note:.
When Er01 or Er02 error message displays, the dehumidification
cycle will stop automatically. The machine will revert to
STANDBY MODE but will still be on unless manually turned off.
Contact Abatement Technologies for service.
When Er03 error message displays, the dehumidification cycle is
still on. Contact Abatement Technologies for service.
Indication Light:
Status
Colors
N/A
Off
Red
On
Green
On
Maintenance
WARNING! Always unplug any dehumidifier before performing
maintenance procedures.
Before Each Use
•
Inspect the electrical cord for damage.
•
Inspect condensate pump drain tube. Make sure the drain
tube is completely unwrapped and not kinked. Failure to
do so can cause water to back up in the pump and leak
out. The control panel may signal this problem by
displaying "ER01
•
Inspect filter. Look for accumulated dust and dirt that
would restrict airflow through the filter into the unit. If any
is visible, vacuum out the debris. Do not wash the filter,
as it will reduce the effectiveness of the electrostatic
material.
Important: Replace the filter after:
•
It has been vacuumed clean 3 times.
•
It has been used on a mold remediation job.
Description
Problem with pump or the drain tube is
kinked.
Check coil temperature sensor at the
side of coil and the sensor cable.
Check ambient temperature sensor in
the front of the coil and the sensor cable.
Description
Machine is off.
Machine is on.
Machine dehumidification cycle is on.