Dell Force10 C300 Quick Start Manual - Page 17
Browse online or download pdf Quick Start Manual for Server Dell Force10 C300. Dell Force10 C300 33 pages. Quick start guide
Installing the Fan Tray
The C-Series chassis contains one field-replaceable fan tray. There are two types
of fan tray that may be installed: one contains six fans that run at varying speeds
depending on system temperature; the other one contains six fans that run at a
constant speed. For both types of trays, air flows through the system toward the
fans (right to left) and is exhausted on fan-side of the chassis. The fan tray is
accessible from the front of the chassis.
WARNING: To ensure proper temperature and airflow control, the fan tray
must always be installed and operating properly.
NOTE: The system does not have an air filter so take special care in making sure
that the installation site and the chassis itself are cleaned regularly.
Step
Task
Slide the fan tray into the fan slot.
1
Gently push on the front of the tray until it stops. The fan tray should be
2
flush with the chassis.
Use a #2 Phillips screwdriver to secure the fan tray into place by
3
tightening the screws at the top and bottom of the fan tray.
C150
0
1
R0
R1
2
3
fnD0003mp
Installing the Hardware
15