Replacing the Server Module Board
The following procedures are required to replace the server module board. You must follow
the procedures in the order given.
Removing the Server Module
CAUTION: See your System Information Guide for complete information about
safety precautions, working inside the computer, and protecting against
electrostatic discharge.
Ensure that the server module's power is off.
1
The blinking green power-on indicator shows that power is available to the system. If
the power-on indicator is solid green, press the module's power button to turn off the
module. See Figure 1-1.
Using a #2 Phillips screwdriver, loosen the captive screw that secures the server
2
module's ejector handle to the front of the server module. See Figure 1-2.
Grasp the server module's handle and rotate the handle down to eject the server
3
module from the chassis. See Figure 1-2.
Grasp the server module and slide it out of the chassis. See Figure 1-2.
4
F i g u r e 1 - 2 .
1-6
Repl aci ng the S er v er Mo dule Bo ard
R e m o v i n g a n d I n s t a l l i n g a S e r v e r M o d u l e
server module handle
server module