Technical Specifications

NOTE: For additional specifications, see your system
Power — Blades
Coin-cell battery
Power — Enclosure
AC/DC power supply (per power supply module) (2700 W)
Wattage
Connector
Heat dissipation
Maximum inrush current
AC/DC power supply (per power supply module) (3000 W)
Wattage
Connector
Col. Lomas Altas
11950 México, D.F.
BMX01
100 V CA to 240 V CA (with 2700 W AC power supply units) or –(48–60) V CC (with
2700 W DC power supply units)
200 V CA to 240 V CA (with 3000 W AC power supply units)
50 Hz/60 Hz or N/A
16 A (x6) or 75 A (x6)
FHB
12 V CC
75 A
HHB
12 V CC
37 A
QHB
12 V CC
35 A
Owner's Manual .
3 V CR2032 Lithium coin cell
2700 W
IEC C20
1205 BTU/hr (maximum)
Under typical line conditions and over the entire system
ambient operating range, the inrush current may reach
55 A per power supply for 10 ms or less.
3000 W
IEC 320