Error: 54 occurred while attempting to create an OS
volume
Description
Array disk (0:x:x) has already been specified as a global hot spare.
or
Selected array disks are part of a similar type of virtual disk (T10 protection and encryption capability) or the array
disks are not part of any virtual disks.
Workaround
Validate all the hard drives and perform one of the following:
•
If any one of the array disks status is non-RAID, change the status to RAID.
•
If any one of the hard drives has failed or is predicted to fail, replace the hard drive.
•
Check if all the array disks are available and online.
•
Check if any array disk is part of virtual disk or hot spare.
Error: -5000 shows unexpected system error message
Description
Could not locate Dell EMC Storage NAS OS configuration file.
OS reinstall media or media reader may be faulty.
Cause
This issue occurs because either the OS reinstallation media, optical drive, or the system is in an invalid state.
Workaround
Restart your system and reinstall the OS reinstallation media. If the issue persists, contact your service provider.
For more information, see the
Error: -5001 shows invalid system error message
Description
This operation is not supported on this system.
Cause
This issue occurs because the operation is not supported on the system.
Workaround
Remove the OS reinstallation media immediately.
Error: -5002 shows unsupported hardware
configuration error
Description
Could not locate a supported RAID controller.
Workaround
Perform one of the following tasks:
•
Ensure that the disk controller card is connected to the internal drives and is properly seated in the correct slot.