Some points of the electrical card are under voltage. Therefore, the installation, the opening and the programming of board have to be done
only by qualified staff. All the operations executed by the user do not require box opening.
Providing the use of a device that ensures omni polar disconnection of power from the control unit. This device may be or an interrupter
(directly connected to the power terminals) with a minimum distance of 3 mm. between the contacts in each pole, or a device integrated into
the power network.
For connecting the card and the motors, we recommend to use cable with double isolation as provided through restrictions and in any case,
individual conductor must have a minimum cross section not less than 1mm² and not more than 2.5mm².
The manufacturer declines all responsibilities for no compliance with these warnings.
This central unit is furnished with a test circuit for the photocells. For wiring these photocells, see diagram on page 5.
It is recommended to check the absorptions of all devices connected to the output of control unit, such as warning lights, photocells, safety
devices and so, according to their limits established on the table of technical features.
The correct functioning of the product is not guarantee in case of non-observance of these limitations.
To maximise the transmitter reach, it is not necessary to pay attention to the placing of the receiving antenna: it must not be positioned near
walls and/or metallic shields. The terminals on shielded cable of the antenna have to be tightly closed.
The corded antenna is necessary for obtaining the highest equipment capacity, otherwise the reach would be reduced to a few meters.
4. Factory settings.
The control board is supplied with the dip.switch set as indicate on the figure beside.
In the table are resumed the functions selectable by these dip-switch.
Function
dip
1
Step-by-step
2
Water hammer
3
Photocells
4
Pre-blinking
5
Condominium function
6
Safety control
Limit switch operating
7
mode
In Closing
Limit switch operating
8
mode
In Opening
9
***
Immediate Automatic
10
re-closing
5. Self-lerning transmitter.
The self-learning procedure of every individual transmitter must always be carried out with the gate closed
5.1 Memorization of the transmitters / of the transmitter of preparation 4 channels
Pressing and releasing the learning taste turn on the flashing light; so, transmit with the
transmitter to learn, considerino that:
The tastes must be learned one by one
With the first button learned "a", the step-by-step order is given.
With the second button learned "b", the "pedestrian" command is imparted.
With the third button learned "c", the DOWN command is given.
With the fourth button learned "d", the UP order is imparted.
It is advisable to learn the a, b, c, d keys sequentially.
When an UP or DOWN button is activated while imparting the instructions (the "c" or "d" button over the transmitter), the blinking light will flash
briefly for indicating that the key was seen from the system. It is very important to verify that each transmission of all the buttons is correctly
received by central unit.
NOTA: The successive learning can now be executed also with the memorized transmitter. The operative modalities are reported here
following:
6-1622192
rev. 14
21/09/2012

SAFETY WARNINGS

Dip OFF
Dip ON
Open-stop
Open-Close
Close-stop
Enabled
Disabled
movement
arrest and rever-
stops
sal of motion
Active
Active
Not active
Active
Enabled
Disabled
Start of slo-
End of opera-
wdown
tion
In closing
Start of slo-
End of opera-
wdown
tion
In opening
***
***
Disabled
Enabled
ITA
Function
dip
1
Step-by-step
2
Water hammer
3
Photocells
4
Pre-binking
5
Condominium function
6
Safety control
Limit switch operating
7
mode
Slowdown functioning
mode
(only if dip 7 is ON)
8
Slowdown functioning
mode
( only if dip 7 is OFF)
9
Open gate
Immediate Automatic re
10
-closing
ENG
FRA
ESP
DEU
POR
Dip OFF
Open-stop-Close
Open-Close
Enabled
movement stops
arrest and reversal
Not active
Not active
Enabled
Beginning of slo-
End of operation
Start of slowdown
Start of slowdown
on limit switch in
OPENING
switch in CLOSING
Limit switch not
End of operation
connected
Symmetrical
Asymmetrical
Disabled
TRANSMITTER
PP
a
b
PEDESTRIAN
c
d
DOWN
UP
Dip ON
Disabled
of motion
Active
Active
Disabled
wdown
on limit
Enabled
,