Miele DA 220-4 Operating And Installation Instructions - Page 15
Browse online or download pdf Operating And Installation Instructions for Ventilation Hood Miele DA 220-4. Miele DA 220-4 36 pages. Ventilation system
Also for Miele DA 220-4: Dimension Manual (2 pages), Operating And Installation Instructions (40 pages)
Reprogramming the timers
The grease filter timer is preset to 30
hours. This time can be lengthened or
shortened to 20, 30, 40, or 50 hours.
– A time of 20 hours should be
programmed in kitchens with
frequent pan or deep frying.
– A time of 20 hours should also be
programmed if the kitchen is only
used occasionally to prevent grease
which has accumulated over a long
period of time from hardening on the
filters making cleaning more difficult.
^ Press the On/Off button to turn off the
fan.
^ Press the Delayed Shut Down and
grease filter buttons at the same time.
The indicator for the grease filter and
one of the "– / +" indicators will flash.
The lit indicator shows the programmed
time:
1st indicator from the left
2nd indicator from the left = 30 hours
3rd indicator from the left
4th indicator from the left
^ Use the "– / +" button to select the
desired time.
^ Save the selection by pressing the
grease filter button.
If the procedure is not saved within 4
minutes of programming, the hood
will automatically default to the "old"
data.
Operation
= 20 hours
= 40 hours
= 50 hours
15