Miele DA 3190 Operating And Installation Instructions - Page 32

Browse online or download pdf Operating And Installation Instructions for Ventilation Hood Miele DA 3190. Miele DA 3190 36 pages. Ventilation system
Also for Miele DA 3190: Operating And Installation Instructions (40 pages), Dimensions (1 pages), Operating And Installation Instructions (40 pages), Operating And Installation Instructions (40 pages), Operating And Installation Instructions (40 pages), Operating And Installation Instructions (40 pages)

Miele DA 3190 Operating And Installation Instructions
Installation

7. Venting

Air extraction mode
^ Complete the venting installation, see
"Air extraction".
Recirculation mode
If the hood cannot be installed for air
extraction the appliance must be
connected for recirculation mode.
For recirculation mode a respective
installation kit is recommended which
can be obtained from Miele.
In addition an active charcoal filter is
needed.
^ The non-return flap is not needed for
the recirculation mode. Pull the
non-return flap off the bracket from
the vent connection.
32
^ Insert the hose from below into the air
outlet grille.
^ Insert the hose from the top though
the opening in the cabinet.
^ Secure the ventilation hose on the
vent connection of the hood using a
hose clip.
The non-return flap is not used in
recirculation mode.
^ Screw the air outlet grille onto the
cabinet top.
Make sure that the slats in the grill
point towards the center of the room
and not towards a wall or the ceiling.
^ Install the Active Charcoal Filter (see
"Cleaning and care").

8. Electrical connection

Refer to the notes in "Electrical
connection" and "Important Safety
Instructions" before connecting to
the mains.
^ Plug in the power cord.