Installation
Recirculation mode
If site conditions are not suitable for the
cooker hood to be used in extraction
mode, the appliance must be set up for
recirculation. A conversion kit, available
through your dealer of from Miele is
required for operating the cooker hood
in recirculation mode. You will also need
a charcoal filter (see "Technical data").
Conversion kit DUU 150 with a plastic
grille is suitable for fitting in a non-
visible area at the top of the wall unit.
Conversion kit DUU 151 with a stainless
steel grille is recommended if the grille
is to be fitted in an area which is visible.
Fit the conversion kit as described in
the installation instructions supplied
with the kit. Make sure that the slats
in the exhaust grille point towards the
38
centre of the room and not towards a
wall or the ceiling.
A non-return flap is not used in
recirculation mode.
Fit the charcoal filter (see "Cleaning
and care").
Power connection
Refer to the notes in "Electrical
connection" and "Warning and safety
instructions" before connecting to
the power supply.
For appliances connected to an
external motor (EXT/EXTA models):
Connect the cooker hood and the
external motor using the connection
cable and the six-pole plug
connector.
Connect the cooker hood to the
power supply.
Electrical connection
This cooker hood is supplied for
connection to an AC 230 V ~ 50 Hz
supply. It must be connected to an
earthed socket which complies with
relevant regulations.
The electrical installation must comply
with VDE 0100 requirements (BS 7671
in the UK).
For increased safety, VDE recommends
in its guideline DIN VDE 0100 Part 739
that you should protect the appliance
with a suitable residual current device
(RCD) with a trip current of 30 mA
(DIN VDE 0664).