Also for Miele DA 424 V EXT: Operating And Installation Instructions (40 pages), Product Dimensions (2 pages), Operating And Installation Instructions (36 pages), Operating And Installation Instructions (36 pages), Operating And Installation Instructions (36 pages), Operating And Installation Instructions (40 pages)

Miele DA 424 V EXT Operating And Installation Manual
Reprogramming the grease filter
timer
The grease filter timer is preset to
30 hours. This time can be lengthened
or shortened to 20, 30, 40 or 50 hours.
– A time of 20 hours should be
programmed in kitchens with
frequent pan or deep frying.
– If you tend to cook fat-free, choose a
longer operating time.
– A time of 20 hours should also be
programmed if the kitchen is only
used occasionally to prevent grease
which has accumulated over a long
period of time from hardening on the
filter, making cleaning more difficult.
^ Press the On/Off button to turn off the
fan.
^ Press the Delayed Shut Down and
grease filter button at the same time.
The indicator for the grease filter timer
and one of the "–/+" indicators will flash.
The lit "–/+" indicator shows the
programmed time:
1st indicator from the left
2nd indicator from the left = 30 hours
3rd indicator from the left
4th indicator from the left
^ Use the "–/+" button to select the
desired time.
^ Store the selection by pressing the
grease filter button.
All the indicator lights go out.
If the procedure is not stored within
4 minutes of programming the hood
will automatically default to the "old"
data.
Operation
= 20 hours
= 40 hours
= 50 hours
15