Connection for air recirculation

Connection for air recirculation
If site conditions are not suitable for the
cooker hood to be used for air extrac-
tion, the appliance must be converted
for recirculation.
The following parts will be required:
– Conversion kit from extraction to re-
circulation (only for units or cooker
hood shafts which do not reach the
ceiling)
– Active charcoal filters
These parts are available from your
Miele Dealer or from the Miele Spare
Parts Department.
Connection –
for units or cooker hood shafts
which do not reach the ceiling
Saw out an opening in the cupboard.
From above, place the hose with the
directional grille through the hole in
the unit onto the exhaust connection
of the cooker hood so that the air out-
let points in the desired direction.
18
NB: on no account should it point to-
wards the wall!
Screw the directional grille to the unit
with two screws.
If there is a ceiling infill, an appropriate
cut-out in the infill must be made.
Insert the active charcoal filters (see
section "Cleaning and care").
Connection –
for cooker hood shafts which reach
the ceiling
Install a directional grille, available
from builders' merchants, in the
upper region of the chimney so that
the air outlet points in the desired di-
rection. NB: on no account should it
point towards the wall!
Attach the recirculation hose.
Insert the active charcoal filters (see
section "Cleaning and care").