Miele DA2210 Operating And Installation Manual - Page 29

Browse online or download pdf Operating And Installation Manual for Ventilation Hood Miele DA2210. Miele DA2210 40 pages. Cooker
Also for Miele DA2210: Operating And Installation Instructions (36 pages), Dimension Manual (1 pages), Operating And Installation Instruction (40 pages), User Manual (40 pages), Operating And Installation Instructions (40 pages), Installation Instructions Manual (19 pages), Operating And Installation Instructions (44 pages)

Miele DA2210 Operating And Installation Manual

Preparation for extraction

^ When using C 150 mm ducting,
secure the exhaust connection
supplied to exhaust ducting with
hose clips.
^ If using C 125 mm ducting, fit the
reducing collar into the exhaust
connection, and secure the exhaust
ducting to the reducing collar with a
hose clip. (See "Connection for air
extraction").
^ Place the exhaust ducting on the fan
connection for the cooker hood.
^ See "Connection for air extraction" for
further instructions on fitting the
ducting.
^ DA 2210: The hood has two exhaust
connections for use with two 150 mm
diameter exhaust hoses.
A Y- adapter is supplied with the
hood. It may be used to feed the
exhaust from both connections to a
200 mm diameter common duct.
dai2717
Installation
29