Also for Miele DA2210: Operating And Installation Instructions (36 pages), Dimension Manual (1 pages), Operating And Installation Manual (40 pages), Operating And Installation Instruction (40 pages), User Manual (40 pages), Installation Instructions Manual (19 pages), Operating And Installation Instructions (44 pages)

Miele DA2210 Operating And Installation Instructions

Cleaning and care

,
Before any cleaning or
maintenance work is carried out,
disconnect the rangehood from the
mains supply. Ensure that:
– it is switched off at the isolator, or
– it is switched off at the wall
socket and the plug removed, or
– the mains fuse is withdrawn, or
– the screw-out fuse is removed
(in countries where this is
applicable).
A range of Miele branded cleaning and
conditioning agents are available to
order through your Miele Chartered
Agent, from Miele or via the internet at
www.miele-shop.com.

Housing

The surfaces and controls are
susceptible to scratches and
abrasions. Please observe the
following cleaning instructions.
^ All external surfaces and controls can
be cleaned using the Original Miele
all purpose microfibre cloth, or with
warm water and a small amount of
washing-up liquid applied with a well
wrung-out soft sponge or cloth.
^ Wipe the surfaces dry using a soft
cloth.
20
Do not use:
– cleaning agents containing soda,
acids, chlorides or solvents,
– abrasive cleaning agents, e.g.
powder cleaners or cream cleaners
and abrasive sponges, as well as pot
scourers or sponges which have
been used previously with abrasive
cleaning agents.
These will damage the surface
material.

Grease filters

The re-usable metal grease filters in the
appliance remove solid particles
(grease, dust, etc.) from the kitchen
vapours, preventing soiling of the
rangehood.
To avoid a build-up of grease, the
grease filters should be cleaned
regularly (at least every 3-4 weeks), but
always clean immediately if the grease
filter indicator lamp comes on.
,
An oversaturated filter is a fire
hazard.