Also for Miele DA2210: Operating And Installation Instructions (36 pages), Dimension Manual (1 pages), Operating And Installation Manual (40 pages), Operating And Installation Instruction (40 pages), User Manual (40 pages), Installation Instructions Manual (19 pages), Operating And Installation Instructions (44 pages)

Miele DA2210 Operating And Installation Instructions
Cleaning and care
^ After replacing the grease filters,
press the grease filter control for
approximately 3 seconds to reset the
operating hours counter.
The indicator lamp will go out.
^ If the grease filters are cleaned
before the operating hours counter
has reached its maximum, the grease
filter control should be pressed for
approximately 6 seconds to reset the
counter.
Fitting and replacing the
charcoal filters
If the rangehood is connected for
recirculation, charcoal filters must be
inserted in addition to the grease filters.
They are designed to absorb cooking
odours and are fitted in the canopy
above the grease filters.
DA 2250, DA 2270: 2 charcoal filters
DA 2210: 4 charcoal filters
New filters can be purchased from
your Miele Chartered Agent or from
Miele. See back cover for contact
details, and "Technical data" for the
model number of the filter.
^ Before fitting or replacing the
charcoal filters, the grease filters
must first be taken out (see previous
section for instructions on how to do
this).
^ Unwrap the charcoal filters.
22
^ Insert the charcoal filters into the
canopy.
^ When fitting for the first time:
Activate the charcoal filter operating
hours counter to suit your
requirements (see "Operation").
^ Replace the grease filters.