Miele DA2280 Operating And Installation Instructions - Page 35

Browse online or download pdf Operating And Installation Instructions for Ventilation Hood Miele DA2280. Miele DA2280 44 pages. Ventilation system
Also for Miele DA2280: Operating And Installation Instructions (36 pages), Dimensions (1 pages), Operating And Installation Manual (40 pages), Operating And Installation Instruction (40 pages), Installation Instructions Manual (19 pages)

Miele DA2280 Operating And Installation Instructions
Setting up for recirculation
mode
If on-site conditions do not allow the
hood to be used in vented mode, the
appliance must be set up for
recirculation. The DUU 151 conversion
kit, available from Miele and Miele
dealers, is required to operate the hood
in recirculation mode. You will also need
a DKF 15-1 OdorFree Charcoal Filter set
(2 filters).
The DA 2210 requires two conversion
kits and two OdorFree Charcoal Filter
sets (4 filters).
 Install the conversion kit as described
in the installation instructions
supplied with the kit. Make sure that
the louvres in the exhaust grille point
towards the center of the room and
not towards a wall or the ceiling.
Non-return flaps are not used in
recirculation mode.
 Install the charcoal filters (see
"Cleaning and care").
Installation
35