Set up for extraction mode
If required, install the non-return flap.
Check that the flap opens easily and
closes by itself.
A non-return flap is used in each of
the two exhaust sockets on the
DA 2210.
Attach the exhaust ducting, e.g.
flexible hose, to the exhaust collar
using a hose clip (available as an
optional accessory). When using
125 mm ducting, fit the reducing
collar supplied into the exhaust
socket (see "Connection for air
extraction").
Place the exhaust ducting on the
exhaust collar for the rangehood.
See "Connection for air extraction"
for further instructions on fitting the
ducting.
DA 2210: The rangehood has two
exhaust sockets for use with two
150 mm diameter exhaust hoses. A
"Y" adapter is supplied with the
rangehood. It may be used to feed
the exhaust from both sockets to a
200 mm common duct.
However, for optimum performance
and minimum operating sound,
exhaust ducting via two separate
ducts is strongly recommended.
dai2699
Installation