Miele Novotronic T 220 Operating Instructions Manual
Installation - venting
Connecting directly to a wall
vent
The best method of venting the dryer
is to connect it directly to the outside
wall of a room. However, it is neces-
sary to insert the wall vent right
through the wall.
Because the vented air is blown di-
rectly outside, and has only a short
distance to go, this system is very ef-
ficient in terms of time and energy
consumption.
^ A wall pipe and a flexible foam gas-
ket must be used (both Miele optional
accessories).
A Before drilling into the wall . . .
. . . read the installation instructions
supplied with the Miele wall pipe.
. . . and study the following dia-
grams.
View from above:
1. Wall pipe
2. Flexible foam gasket
34
Side view:
1. Wall pipe
2. Flexible foam gasket
B Insert the ring adapter (1) into the
wall pipe.
C Fit the foam gasket (3) on to the con-
necting piece (2) on the wall pipe
and push the dryer up against the
wall.