Miele TOUCHTRONIC T 9802 Operating And Installation Instructions - Page 37

Browse online or download pdf Operating And Installation Instructions for Dryer Miele TOUCHTRONIC T 9802. Miele TOUCHTRONIC T 9802 44 pages. Vented dryer
Also for Miele TOUCHTRONIC T 9802: Operating And Installation Instructions (44 pages)

How to calculate the effective
duct length
The overall duct length will determine
the duct diameter (see the "Additional
duct lengths" table). In Canada the
exhaust duct must be 4" (102 mm) in
diameter.
^ Measure the actual duct length
needed to go from the dryer's
exhaust connection to the vent outlet:
1. Establish the number of elbows or
bends necessary, noting the type of
bend, angle and radius involved
(see the "Additional duct lengths"
table).
2. Add the additional duct length (as
derived by using the values
specified in the "Additional duct
lengths" table) to the actual duct
length to get the effective length.
Note:
Maximum effective duct lengths:
4" (100 mm) diameter
5" (125 mm) diameter
6" (150 mm) diameter
* For rigid ducting only!
Local building codes may vary.
When flexible metal duct (transition
duct) is permissible by local building
codes, the total length must not
exceed 7'10" (2.4 m).
See the "Additional duct lengths"
table for more information on
maximum duct lengths and number
of bends.
Effective duct lengths over 66 ft (20 m)
require a larger duct diameter.
Longer ducts may lead to slight
decreases in dryer efficiency if the
necessary duct diameter is not
followed.
Installation
66 ft (20 m)
115 ft (35 m)
108 ft (33 m)
33