System Disinfection
Use the following steps to fully disinfect the lines throughout the entire home
after new installation, replacement of UV Lamp, or after loss of power.
1. Remove the filter cartridge from the Post-Filter and fill it with 1-2 cups of
household bleach (most are 5.25% chlorine). Replace the sump and slowly
turn on the water supply.
2. Choose a water outlet. Turn on the water and run water until bleach can
be smelled to ensure disinfection. Repeat this step for all faucets, toilets,
shower heads, appliances, outdoor taps, etc. Once complete, wait at least
30 minutes before continuing to the next step.
3. Put the filter cartridge back into the Post-Filter and flush the chlorine
solution by opening all faucets in the home until chlorine can no longer
be detected.
Cleaning the Quartz Sleeve
The Quartz Sleeve should be cleaned at least once every 12 months,
but depending on water quality, may require cleaning more often.
1. Unplug UV Filter from the electrical outlet.
2. Turn off the main water inlet valve or turn off the inlet valve on the
Pro-Kit to enable the bypass system.
WARNING
3. Using a screwdriver, remove the Ground Screw from the Ground Lug
on the UV Reactor.
4. Unplug the Lamp Connector from the UV Reactor by pushing the Lamp
Connector in and turning the Lamp Connector 1/4 turn counter-clockwise.
Disconnect the lamp connector from the lamp.
WARNING
5. Remove the UV Lamp.
NOTE: DO NOT touch the UV Bulb. Only touch the ceramic ends.
6. Unscrew the Gland Nut from the UV Reactor exposing the end of the
Quartz Sleeve.
(Cont. on next page)
DO NOT turn off water or drain water from lines before
disconnecting power to the UV Filter.
The UV Lamp may be hot!
USE & CARE