aquatherm AT800 Installation Manual - Page 3

Browse online or download pdf Installation Manual for Heat Pump aquatherm AT800. aquatherm AT800 8 pages. Swimming pool & spa heat pumps “black cabinet” with analog controls series only
Also for aquatherm AT800: Owner Operational Manual (12 pages), Installation Manual (16 pages)

E. "DIGITAL LOGIC" CONTROL PANEL INFORMATION
POWER button is lit when heater is turned on.
3. MODE SELECT BUTTONS-POOL or SPA: The heater has two thermostat modes for two dif-
ferent desired temperature settings, one for pool mode and one for spa mode. If you do not have
a spa, use the pool mode only. If you have a spa/pool combination, you have options available to
automate pool and spa heating functions.
4. THERMOSTAT BUTTONS: Pressing the + button will raise the set temperature. Pressing the
- button will lower the set temperature. When either button is pressed the LED display will begin
to flash. The flashing numbers indicate the thermostat setting.
5. GREEN HEATING LIGHT: This light indicates that the unit is heating and the compressor is
running. The compressor starts after a 3 to 5 minute time delay. NOTE: The water pump must be
running in order for the heater to run.
6. OPTIONAL WATER PUMP TIME CLOCK OVERRIDE OPERATION When the T.C.O.
button is set to the ON mode, the Time Clock Override feature is designed to start the water pump
when the pool requires heat. Once the pool is up to the set temperature the heater will stop and
then 5 minuets later the water pump will stop. When this button is set to the OFF mode, the heater
will operate only when the water pump is running during the timed period set on the time clock.
NOTE: The time clock override works best if used during cooler weather conditions where the pool
is losing more than 8 to 10 degrees over night or when the pool is being heated from "dead cold".
NOTE: If the time clock override starts the water pump and the thermostat does not continue to
call for heat for at least 5 minutes, the control will shut the water pump and heater off. Thereafter,
it will not re-attempt to start the water pump for 4 hours. This 4 hour delay can be bypassed by
pressing the T.C.O. button off then back on. NOTE: When the T.C.O. button is activated while in
"spa mode" the water pump will run the entire time you are in spa mode. When you switch back
to pool mode there will be a 5 minute delay before the water pump shuts off.
LED STATUS CODE READOUTS:
LF This light indicates there is no water flow through the heater. The heater is designed to shut off
when the water pump is not pumping water through the heater. If LF is on while the water pump is
running, the water pump may not be supplying enough flow for the heater to operate properly.
DF This readout indicates that the internal defrost safety control has disabled the heater. During cold
weather where the air temperature drops below approximately 45 to 50 degrees (depending on humid-
ity), the defrost sensor is designed to disable the compressor only. When the air temperature has
increased to the operational range the compressor will come on and start heating again.
HP This readout out indicates high refrigerant pressure. The high refrigerant pressure switch is designed
to shut the compressor and fan off if a heat buildup occurs for whatever reason. Typically the high
refrigerant pressure switch will trip if the water flow through the heater is restricted. It may also trip if
the air flow is restricted through the heater. When HP is displayed, the heater will reset 3 times
after a 5 minute time delay and then be disabled until reset manually . To reset, turn the unit
off then back on.
Titanium Instal Manuals.indd 3
LED READOUT:
1. GREEN POWER LIGHT: This light indicates that
the heater has control power. WARNING: This is not
a line power indicator and caution should be used since
more than one power disconnection may be required
to isolate the heater electrically. If the optional Time
Clock Override is installed, you must shut off the water
pumps main power disconnect.
2. HEATER ON/OFF BUTTON: Green light on
-14-
A. UNIT DESCRIPTION
CONTROLS with
LED READOUT
WATER OUT
2" MALE THREADED
PIPE
NOTICE: UNIT REQUIRES TWO, 2 INCH
FEMALE ADAPTORS FOR PLUMBING CON-
NECTIONS
-3-
AIR DISCHARGE FAN
WARNING: ROTATING
BLADE KEEP HANDS & HAIR
CLEAR!
SERIAL
NUMBER
PLATE
ELECTRICAL IN-
STALLATION
PORT(S)
WATER IN
2" MALE THREADED
PIPE
WARNING
DANGER FROM ELECTRICAL
SHOCK & ROTATING FAN !
SHUT OFF ALL POWER
BEFORE SERVICING !
CAUTION: MORE THAN ONE
DISCONNECTION MAY BE
REQUIRED TO ELIMINATE ALL
POWER TO THIS UNIT INCLUD-
ING POWER TO THE OPTIONAL
TIME CLOCK OVERRIDE !