Axor Citterio Select 230 2jet sBox 39862007 Installation Manual - Page 3

Browse online or download pdf Installation Manual for Plumbing Product Axor Citterio Select 230 2jet sBox 39862007. Axor Citterio Select 230 2jet sBox 39862007 20 pages.

S A F E T Y N O T E S
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and
tested as per the applicable standards.
⁄ The plumbing codes applicable in the respective
countries must be observed.
⁄ During initial start-up and after servicing, air in the
fittings can cause noise. After switching the jet on and
off about 15 times, the noise will stop.
T E C H N I C A L D A T A
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Thermal disinfection:
The product is exclusively designed for drinking water!
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
A D J U S T M E N T (see page 11)
To adjust the hot water limiter. Using a hot water
limiter in combination with a continuous flow
water heater is not recommended.
M A I N T E N A N C E (see page 15 )
The check valves must be checked regularly
according to EN 806-5 in accordance with
F A U L T
⁄ Mixer stiff
⁄ Mixer dripping
⁄ Water escaping at the threaded base ⁄ connection hoses not completely
⁄ Hot water temperature too low
⁄ Low flow with Select valve after valve
replacement
⁄ Select button stiff
A S S E M B L Y (see page 04 )
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
70°C ⁄ 4 min
C A U S E
⁄ Cartridge defective, calcified
⁄ Cartridge defective
screwed into basic body
⁄ O-ring at the connection hose defec-
tive.
⁄ Hot water limiter incorrectly set
⁄ Improper Select valve installed
⁄ Select button soiled
national or regional regulations (at least once a
year).
D I M E N S I O N S (see page 17)
F L O W D I A G R A M (see page 17)
S P A R E P A R T S (see page 18 )
S P E C I A L A C C E S S O R I E S
(order as an extra)
extension #43333000 (see page 14)
C L E A N I N G (see page 12 )
O P E R A T I O N (see page 16 )
⁄ Hansgrohe recommends not to use as drinking
water the first half liter of water drawn in the
morning or after a prolonged period of
non-use.
⁄ Minor leaking may occur briefly at the spout
when opening the fitting via the lever.
⁄ Use the lever to open the tap and set the
desired temperature. The water flow can be
paused by pressing the Select button on the
face side of the spout. When the tap is not
used for a longer period of time, f.e. when
retiring at night or leaving the house, it must be
closed completely by means of the lever.
R E M E D Y
⁄ Exchange cartridge
⁄ Exchange cartridge
⁄ Tighten connection hoses by hand
⁄ Exchange O-ring
⁄ Set hot water limiter
⁄ Replace Select valve (#98463000)
⁄ Clean Select button and grease
14x1,5 O-ring (see page 18)
0 3
EN