Architectural Area Lighting LC5 Installation Instructions Manual - Page 4
Browse online or download pdf Installation Instructions Manual for Outdoor Light Architectural Area Lighting LC5. Architectural Area Lighting LC5 16 pages.
INSTALLATION INSTRUCTIONS
6.00"
1.079"
8.50"
3.03"
A
5.375"
2.046"
3.75"
BALLAST HOUSING MOUNTING
DETAIL ORIENTATION
MOUNTING SURFACE
SEE NOTE #4 & #12 THRU #15
WIRE CONNECTORS
(BY OTHERS)
J-BOX (BY OTHERS)
16555 East Gale Avenue
City of Industry, CA 91745
(626)968-5666
WALL MOUNT CURVED ARMS
FIXTURE INSTALLATION
1) DRILL BOLT HOLES AND WIREWAY IN ACCORD TO THE
O
(4)
0.531"
SUPPLIED MOUNTING TEMPLATE.
2) TURN OFF POWER.
3) ADJUST FIXTURE HEAD TO THE DESIRE POSITION
3.54"
A
AND SECURE WITH (2) BUTTON HEAD SCREWS.
4) LOOSEN BOTH SCREWS LOCATED BELOW BALLAST HOUSING
ALLOW DOOR TO HANG DOWNWARD. DISCONNECT WIRE
WIREWAY
HARNESS BETWEEN BALLAST AND FLEXIBLE CONDUIT.
REMOVE BALLAST TRAY.
1.03"
A
5) SECURE BALLAST HOUSING TO MOUNTING SURFACE
WITH APPROPRIATE HARDWARE (SUPPLIED BY OTHERS).
6) RE-INSTALL BALLAST TRAY AND CONNECT WIRE HARNESS.
7) MAKE WIRE CONNECTIONS FROM BALLAST HOUSING
TO INCOMING LINES FROM WALL. ( NOTE: ASSEMBLY MUST BE
GROUNDED TO IMCOMING EQUIPMENT GROUND SUPPLY).
8) SECURE DOOR TO HOUSING BY TIGHTENING BOTH SCREWS.
9) APPLY CONTINUOUS BEAD OF SILICONE SEALANT ALL
AROUND BALLAST HOUSING AND MOUNTING SURFACE.
(SILICONE SUPPLIED BY OTHERS).
(2) BUTTON
LAMP INSTALLATION
10) TO INSTALL LAMP, INSERT FINGERS INTO SLOTS
AND PULL BOTH LATCHES BACK SIMULTANEOUSLY.
11) OPEN THE BOTTOM HALF HOUSING AND INSTALL PROPER
LAMP (BY OTHERS). CLOSE BOTTOM HALF HOUSING, MAKE
SURE LATCHES SNAP BACK TO ITS ORIGINAL POSITION.
BOLTS & WASHERS
SUPPLIED BY OTHERS
SERVICING BALLAST
12) DISCONNECT ALL POWER.
13) LOOSEN SCREWS LOCATED BELOW BALLAST
HOUSING. ALLOW DOOR TO HANG DOWNWARD.
14) SERVICE BALLAST AS NEEDED.
15) CLOSE BALLAST TRAY AND SECURE
ON THE HOUSING WITH (2) SCREWS.
CATALOG NUMBER
WSC & WLC
FIXTURE HEAD
SEE NOTE #10 & #11
DATE
APPRVD
PART NO.
DATE
REV.
04/14/2008
A
A96267