Cisco AJ732A - MDS 9134 Fabric Switch Release Note - Page 45

Browse online or download pdf Release Note for Switch Cisco AJ732A - MDS 9134 Fabric Switch. Cisco AJ732A - MDS 9134 Fabric Switch 48 pages. Converged network switches for nx-os 4.0(1a)n1(1)
Also for Cisco AJ732A - MDS 9134 Fabric Switch: Configuration Manual (49 pages), Release Note (44 pages), Release Note (44 pages), Release Note (36 pages), Release Note (26 pages), Release Note (22 pages), Quick Reference Manual (14 pages), Release Note (3 pages)

Cisco AJ732A -  MDS 9134 Fabric Switch Release Note
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m

Open Caveats

Related Documentation

The documentation set for NX-OS for the Cisco MDS 9000 Family includes the following documents.
To find a document online, access the following web site:
http://www.cisco.com/en/US/partner/products/ps5989/tsd_products_support_series_home.html
OL-19964-02
Workaround: This issue is resolved.
CSCsz22811
Symptom: Compression throughput on the MSM-18/4 module has been improved.
Workaround: This issue is resolved.
CSCtb80346
Symptom: When an SFP is removed because a port if Administratively Down or Out of Service, a
syslog message should be generated.
Workaround: This issue is resolved.
CSCta22244
Symptom: On MDS switches running NX-OS Release 4.2(1a), an fctrace command or fcping
command will not show the correct path to the target switch if any of the switches are connected
through an ISL using any of the ports of the following modules:
DS-X9248-48K9: 4/44-Port 8-Gbps Host-Optimized Fibre Channel Switching Module
DS-X9248-96K9: 48-Port 8-Gbps Fibre Channel Switching Module
DS-X9224-96K9: 24-Port 8-Gbps Fibre Channel Switching Module
The output of an fctrace or fcping command will not show any information about the switches
connected through the ports of these modules.
Workaround: None.
CSCsq20408
Symptom: The show startup command displays aspects of the running configuration when SANtap
is configured and/or SANtap objects are created. When a user creates objects such as a CVT or DVT,
the configuration is showing in the running-configuration and in the startup-configuration without
copying the configuration into the startup-configuration.
Workaround: Issue a copy running-config startup-config command whenever you create objects
such as a CVT or DVT so that the running-configuration and startup-configuration are synchronized.
CSCsy37951
Symptom: The Trunking F PortChannels feature is not available in NX-OS Release 4.1(1x);
however, a downgrade from Release 4.1(3a) or later to Release 4.1(1x) is nondisruptive, even when
the Trunking F PortChannels feature is enabled (using the feature fport-channel-trunk command)
while running Release 4.1(3a) or later.
Workaround: If a downgrade to Release 4.1(1x) is performed when the Trunking F PortChannels
feature is enabled, the switch will be in an inconsistent state. You must reload the switch after a
downgrade to Release 4.1(1x).
Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 4.2(1a)
Related Documentation
45