Cisco AJ732A - MDS 9134 Fabric Switch Release Note - Page 39

Browse online or download pdf Release Note for Switch Cisco AJ732A - MDS 9134 Fabric Switch. Cisco AJ732A - MDS 9134 Fabric Switch 44 pages. Converged network switches for nx-os 4.0(1a)n1(1)
Also for Cisco AJ732A - MDS 9134 Fabric Switch: Configuration Manual (49 pages), Release Note (48 pages), Release Note (44 pages), Release Note (36 pages), Release Note (26 pages), Release Note (22 pages), Quick Reference Manual (14 pages), Release Note (3 pages)

Cisco AJ732A -  MDS 9134 Fabric Switch Release Note
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Call Trace:
[<e1db8a00>]
[<e1dab17c>]
[<c001ea20>]
[<c0001aa8>]
NIP: E1DB5854 XER: 00000000 LR: E1DB5854 SP: C01B3BE0 REGS: c01b3b30
TRAP: 0200
MSR: 00021000 EE: 0 PR: 0 FP: 0 ME: 1 IR/DR: 00
DEAR: 00000000, ESR: 00000005
MCSRR0: C00044A4, MCSRR1: 00021000, MCAR: 00000000
MCSR: 10000000 MCAR: 00000000 MCPSUMR: 00000000
L2ERRDET: 00000000 L2ERRATTR: 00000000 L2ERRADDR: 00000000
L2ERRCTL: 00000000 L2RSVD: 00000000 PORPLLSR: 00464154
DDRERRDET: 00000000 DDRERRATTR: 00000000 DDRERRADDR: 00000000 TASK =
c01b21d0[0] 'swapper' Last syscall: 120 last math 00000000 last
altivec 00000000 last spe 00000000
................
...............
Workaround: This issue is resolved.
CSCsw78035
Symptom: When FlexAttach is enabled on the switch, the physical pWWN in the FCNS registration
response is not rewritten with the virtual pWWN.
Workaround: This issue is resolved.
CSCsy16228
Symptom: Standard variables and user-defined variables are not being substituted in scripts,
scheduler jobs, and the CLI.
Workaround: This issue is resolved.
CSCso31754
Symptom: IVR does not finish a domain capture which stops the export of IVR devices.
Workaround: This issue is resolved.
CSCsk91974
Symptom: When you issue the show tech-support sme or the show klm internal isapi_scsi command
after attaching to a module, you may see this error message:
issue does not affect the actual tech-support log.
Workaround: This issue is resolved.
CSCsk73654
Symptom: In certain tape libraries, the tape drives are exported as LUNs. If these target ports are already
a part of a Cisco SME configuration and new tape drives are added as LUNs, the new tape drives will not
be discovered during a Cisco SME tape group or tape device configuration.
Workaround: This issue is resolved.
CSCso50663
Symptom: The following syslog message is displayed:
OL-14116-11
[<c0007298>] [<c0018e44>] [<c000464c>] [<c00041f8>] [<e1db5854>]
[<e1db5c24>] [<e1db5944>] [<e1dcdafc>] [<e1da8704>] [<e1daad58>]
[<e1dab4d0>] [<e1d55db8>] [<c001eccc>] [<c00224e8>] [<c001eb98>]
[<c001e654>] [<c00058d0>] [<c00041f0>] [<c0005e20>] [<c0005e34>]
[<c01c9610>] [<c0000394>]
Tainted: PF
Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.3(3)
cat: write error: Bad address
Caveats
. This
39