Technical data
•
Minimum voltage at IN1 and IN2 to be interpreted as "1": 13 V DC
•
STO reaction time (shortest detectable break): 1 ms
•
STO response time: 2 ms (typical), 5 ms (maximum)
•
Fault detection time: Channels in different states for longer than 200 ms
•
Fault reaction time: Fault detection time + 10 ms
•
STO fault indication (parameter
•
STO warning indication (parameter
•
Safety integrity level (EN 62061): SIL 3
•
Performance level (EN ISO 13849-1): PL e
The drive STO is a type A safety component as defined in IEC 61508-2.
For the full safety data, exact failure rates and failure modes of the STO function, refer to the drive hardware manual.
Markings
The applicable markings are shown on the type designation label of the drive.
CE
ROHS
Related documents
Document
ACQ80-01 (30 kW to 55 kW) Drive HW manual
ACQ80 standard control program firmware manual
ACx-AP-x assistant control panels user's manual
Drive Composer PC tool user's manual
Declaration of Conformity
EU Declaration of Conformity
Machinery Directive 2006/42/EC
We
Manufacturer: ABB India Limited
nd
Address:
Plot No 5 &6 , 2
Phase , Peenya Industrial Area ,Bangalore,560058, India
Phone:
+91 80 22949359
Declare under our sole responsibility that the following product:
Frequency converter
ACQ80
ACQ80-04 (frame sizes R0-R3) and ACQ80-01 (frame sizes R4-R5)
with regard to the safety function
Safe torque-off
is in conformity with all the relevant safety component requirements of the EU Machinery Directive
2006/42/EC, when the listed safety function is used for safety component functionality.
The following harmonized standards have been applied:
EN 61800-5-2:2007
Adjustable speed electrical power drive systems –
Part 5-2: Safety requirements - Functional
EN 62061:2021
Safety of machinery – Functional safety of safety-related electrical,
electronic and programmable electronic control systems
EN ISO 13849-1:2015
Safety of machinery – Safety-related parts of control systems.
Part 1: General principles for design
EN ISO 13849-2:2012
Safety of machinery – Safety-related parts of the control systems.
Part 2: Validation
EN 60204-1:2018
Safety of machinery – Electrical equipment of machines –
Part 1: General requirements
1/2
31.22
) delay: < 500 ms
31.22
) delay: < 1000 ms
RCM
WEEE
3AXD10000715412
IMS template code: 3AFE011906, Rev. C
TÜV Nord
Solar impulse
The following other standard has been applied:
IEC 61508:2010, parts 1-2
Functional safety of electrical / electronic / programmable
electronic safety-related systems
IEC 61800-5-2:2016
Adjustable speed electrical power drive systems –
Part 5-2: Safety requirements - Functional
The product referred in this declaration of conformity fulfils the relevant provisions of other
European Union directives which are notified in a single EU declaration of conformity
3AXD10000715392.
Person authorized to compile the technical file 3AXD10000715648:
Name and address: Jussi Vesti, Hiomotie 13, 00380 Helsinki, Finland
th
Bangalore, 15
March 2023
Signed for and on behalf of:
AR Madhusudhan
Vice President, MODP
ABB India Limited
2/2
13
Code (English)
3AXD50001017101
3AXD50000170654
3AUA0000085685
3AUA0000094606
Laxmikantha shenoy
Manager , Prodcut Engineering
ABB India Limited
3AXD10000715412