Table 1 lists the boot configuration capabilities of the supported operating systems .
Table 1 . Local Boot and Boot from SAN Configuration Capabilities by Operating System (X signifies available capability)
RHEL 5 .x, 6 .x – Local Boot
RHEL 5 .x, 6 .x – Boot from SAN
SLES 11 – Local Boot
SLES 11 – Boot from SAN
XS – Local Boot
XS – Boot from SAN
ESX 5 .x – Local Boot
ESX 5 .x – Boot from SAN

Displaying fnic_max_qdepth Parameter Value

The current and postconfiguration value of the fnic_max_qdepth parameter can be displayed using the following commands .
RHEL 6 .x / SLES11 / XS
1 . To display the current fnic_max_qdepth, run the following command:
# cat /sys/module/parameters/fnic_max_qdepth
2 . To display the current fnic_max_qdepth on a per-LUN basis, which is relevant if the value was changed using the run-time
configuration for newly discovered LUNs, run the following command at the command-line interface (CLI) (install lsscsi if
not already installed):
# lsscsi –l
ESX 5 .x
1 . From the ESX CLI, run the following command (the fnic_max_qdepth parameter will not be listed until it has been explicitly
set per the configuration instructions below):
# cat /etc/vmware/esx .conf |grep fnic
Results:
/vmkernel/module/fnic/options = fnic_max_qdepth=128
2 . From the ESX CLI, run the following esxcli command (the fnic_max_qdepth value will be empty until the fnic_max_qdepth
parameter has been explicitly set per the configuration instructions below):
# esxcli system module parameters list –m fnic
Results:
Name
---------------
----
fnic_max_qdepth
uint 128
4 © 2014 Cisco and/or its affiliates . All rights reserved .
Boot Time
X
X
X
X
X
X
X
X
Type
Value
Description
-----
----------------------------------
Queue depth to report for each LUN
Load Time
Run Time
X
X
X
X
X
X
X
X
X