Acuity Brands eldoLED ECOdrive 240/M Installation And Operation Manual - Page 3

Browse online or download pdf Installation And Operation Manual for Controller Acuity Brands eldoLED ECOdrive 240/M. Acuity Brands eldoLED ECOdrive 240/M 3 pages. Pulse dimming

Acuity Brands eldoLED ECOdrive 240/M Installation And Operation Manual
A
Small delays at maximum
and minimum levels
B
Synchronization
with long button push-
end-hold at minimum and
maximum levels
C
Reset
with long button push-
end-hold at minimum and
maximum levels
Power-up conditions:
• During power-up with mains-switch connected to DALI-input, Pulse dimming commands are
not accepted.
• During power-up with DALI control-lines connected to DALI-input, DALI-commands are
accepted.
• After power cycle: power on level will be the last light level before power cycle.
Power on level will be the last light level before power cycle.
© 2019 eldoLED. All rights reserved. Prelim All content contained herein is subject to change without prior notice.
300ms
Small delays allow user to release the
button when targeting maximum or
minimum intensity.
> 10s
With a push-and-hold longer than 10
seconds, all LED drivers connected to
the same push button switch will
synchronize at a uniform
(minimum/maximum) light level, when
having the same direction of fading.
This process can be applied at any
time during normal operation if any
individual driver is unsynchronized.
> 25s
With a push-and-hold longer than 25
seconds, all LED drivers connected to
the same push button switch will reset to
factory settings.
This may be required when the
direction of fading is not the same
after synchronization.