Whirlpool UXT3036AY Installation Instructions And Use And Care Manual - Page 8

Browse online or download pdf Installation Instructions And Use And Care Manual for Ventilation Hood Whirlpool UXT3036AY. Whirlpool UXT3036AY 32 pages. 30" (76.2 cm) and 36" (91.4 cm) range hood
Also for Whirlpool UXT3036AY: Installation Instructions And Use & Care Manual (36 pages), Installation Instructions And Use & Care Manual (28 pages)

Whirlpool UXT3036AY Installation Instructions And Use And Care Manual
Style 1 - Cut Openings for 3¼" x 10" (8.3 cm x 25.4 cm)
Rectangular Vent System
Roof Venting
To make a 4 " x 10½" (10.8 cm x 26.7 cm) rectangular cutout
on the underside of cabinet top and bottom:
1. Mark lines
" (1.3 cm) and 4 " (12.1 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
4. Repeat steps 1-3 for the underside of the top of the cabinet.
Cabinet cutouts
*From wall, not cabinet frame
Wall Venting
To make a 3½" x 10½" (8.9 cm x 26.7 cm) rectangle in the
wall:
1. Make 2 lines by measuring
down from underside of cabinet and mark on the centerline
on the back wall.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the wall.
3. Use saber or keyhole saw to cut a rectangular opening in the
wall for the vent.
Cabinet
front
"
(0.9 cm)
"
(9.8 cm)
(13.3 cm)
Style 2 - Cut Openings for 3¼" x 10" (8.3 x 25.4 cm)
Rectangular Vent to Round Vent Transition
Roof Venting
To make a 4 " x 10½" (10.8 cm x 26.7 cm) rectangular cutout
on the underside of cabinet bottom:
1. Mark lines
" (1.3 cm) and 4 " (12.1 cm) from the back wall
on the centerline of the underside of cabinet.
2. Mark lines 5¼" (13.3 cm) to the right and left of the centerline
on the underside of cabinet.
8
* " (1.3 cm)
5 / "
*4 "
(13.3 cm)
(12.1 cm)
5 / "
(13.3 cm)
" (0.9 cm) and 3 " (9.8 cm)
Centerline
5 "
5 "
(13.3 cm)
3. Use saber or keyhole saw to cut a rectangular opening for
vent.
(12.1 cm)
*From wall, not cabinet frame
To make a circular vent opening on the underside of the
cabinet top:
1. Mark a centerline on the underside of the top of cabinet.
2. Mark a line " (12.7 cm) from the back wall on the underside
of the top of cabinet.
3. Use a compass or a circle template to draw a circle with a
diameter that is ¼" (0.64 cm) larger than the vent.
4. Use saber or keyhole saw to cut the circular vent opening.
Circular vent opening
*5"
(12.7 cm)
*From wall, not
cabinet frame
Style 3 - Cut Openings for 7" (17.8 cm) Round Vent
To make a circular vent openings on the underside of the
cabinet top and bottom:
1. Mark a centerline on the underside of the top of cabinet.
2. Mark a line " (12.7 cm) from the back wall on the underside
of the top and bottom of cabinet.
3. Use a compass or a circle template to draw a circle with a
diameter that is ¼" (0.64 cm) larger than the vent.
4. Use saber or keyhole saw to cut the circular vent opening.
*5"
(12.7 cm)
*From wall, not
cabinet frame
* " (1.3 cm)
5 / "
*4 "
(13.3 cm)
5 / "
(13.3 cm)
Cabinet
cutouts
7 / " (18.4 cm) diam.