Alderlea T4 Installation & Operation Manual - Page 19
Browse online or download pdf Installation & Operation Manual for Wood stove Alderlea T4. Alderlea T4 20 pages. Cast iron wood stove
REAR VIEW
LABEL LOCATION
230611-20 ALT4
Label
CERTIFIED FOR CANADA AND U.S.A.
LISTED ROOM HEATER, SOLID FUEL TYPE.
ALSO FOR USE IN MOBILE HOMES
TESTED TO CAN/ULC S627-M93 AND UL 1482-98
WN# 16405
• INSTALL AND USE IN ACCORDANCE WITH THE MANUFACTURER'S
INSTALLATION AND OPERATING INSTRUCTIONS.
• CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS,
INSTALLATION PERMIT AND INSPECTION IN YOUR AREA.
• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE (USA. ONLY).
• USE 6 INCH / 150MM DIAMETER MINIMUM 24 MSG BLACK OR LISTED CONNECTOR.
• CONNECT TO A LINED MASONRY CHIMNEY SUITABLE FOR USE WITH SOLID FUELS.
• DO NOT OBSTRUCT THE SPACE BENEATH THE HEATER.
• SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED WHEN PASSING
A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING.
• DO NOT PASS A CHIMNEY CONNECTOR THROUGH A COMBUSTIBLE WALL OR CEILING.
• MINIMUM CLEARANCE BETWEEN SINGLE WALL CHIMNEY CONNECTOR AND COMBUSTIBLE MATERIALS-18INCHES/
455MM. CLEARANCE MAY BE REDUCED BY THE USE OF LISTED PIPE SHIELDS, WALL PROTECTORS OR OTHER
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
RESIDENTIAL INSTALLATION
USING SINGLE WALL CONNECTOR
VERTICAL CONNECTOR
A. SIDEWALL TO UNIT
14 IN. / 355 MM
B. BACKWALL TO UNIT
15 IN. / 381 MM
C. CORNER TO UNIT
10 IN. / 254 MM
D. SIDEWALL TO CONNECTOR
23 IN. / 585 MM
E. BACKWALL TO CONNECTOR
18 IN. / 457 MM
F. CORNER TO CONNECTOR
19 IN. / 483 MM
MEANS APPROVED BY LOCAL BUILDING OR FIRE OFFICIALS.
HORIZONTAL CONNECTOR NOT PERMITTED IN MOBILE HOMES
AS TESTED - PIPE SHIELD MAY BE REQUIRED BY LOCAL AUTHORITIES.
* COMBUSTIBLE ALCOVE SIZE : DEPTH - 3 FT. / .91 M MAX., HEIGHT 7 FT. / 2.1 M MIN., WIDTH 4 FT. / 1.2 M MIN.
COMBUSTIBLE FLOOR MUST BE PROTECTED BY A CONTINUOUS NON-COMBUSTIBLE MATERIAL EXTENDED TO THE
FRONT, SIDES AND BACK AS INDICATED.
IN CANADA
G.
18 INCHES / 455 MM
H.
8 INCHES / 200 MM
I.
8 INCHES / 200 MM
IN U.S.A.
G.
16 INCHES / 405 MM
H.
4 INCHES / 102 MM
I.
0 INCHES / 0 MM
• COMPONENTS REQUIRED FOR MOBILE HOME AND ALCOVE INSTALLATION: OUTSIDE AIR KIT, AND ONE OF THE
FOLLOWING LISTED CONNECTORS: SECURITY MODELS DP OR DC, OLIVER MACLEOD MODEL PV, RYDER MODEL
E VENT, SELKIRK METALBESTOS MODEL DS, METAL FAB MODEL DW, AMERI-TEC MODEL DBSP, INDUSTRIAL
CHIMNEY MODEL EXCEL ULTRA-BLACK, OR SIMPSON DURA-VENT MODEL DVL IN COMBINATION WITH ONE OF THE
FOLLOWING COMPATIBLE CHIMNEY SYSTEMS:
IN CANADA - SECURITY MODEL S2100, OLIVER MACLEOD PROJET MODEL HT 3000, SELKIRK SENTINEL MODEL CF,
INDUSTRIAL CHIMNEY MODEL EXCEL 2100, ENERGY VENT COMMANDER 5000.
IN USA - SECURITY MODEL ASHT OR S2100, OLIVER MACLEOD MODEL 3103 OR HT 3000, SELKIRK METALBESTOS
MODEL SS II, METAL FAB MODEL 2100, AMERI-TEC MODEL HS, INDUSTRIAL CHIMNEY MODEL EXCEL 103HT, SIMP-
SON DURA-VENT MODEL DURA/PLUS AND DURA TECH.
USE COMPONENTS SPECIFIED IN PACIFIC ENERGY INSTALLATION INSTRUCTIONS.
• APPLIANCE MUST BE INSTALLED WITH PEDESTAL OR LEG KIT ATTACHED.
• OPTIONAL COMPONENTS - FAN KIT, FAN ELECTRICAL RATING: 115V, 60HZ, 80WATTS.
DO NOT ROUTE POWER CORD BENEATH HEATER.
• CAUTION: RISK OF EXCESSIVE TEMPERATURES - KEEP ASH DUMP CLOSED DURING FIRING OF THE HEATER.
• OPERATE ONLY WITH FEED DOOR CLOSED. OPEN TO FEED FIRE ONLY.
• KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIALS WELL AWAY FROM HEATER.
• REPLACE GLASS ONLY WITH CERAMIC GLASS.
HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN
BURNS. SEE NAMEPLATE AND INSTRUCTIONS.
U.S. ENVIRONMENTAL PROTECTION
AGENCY CERTIFIED TO COMPLY WITH JULY,
1990, PARTICULATE EMISSION STANDARDS
210509
19
C
SERIES:
RESIDENTIAL CLOSE CLEARANCE
INSTALLATION
USING DOUBLE WALL CONNECTOR
VERTICAL CONNECTOR
HORIZONTAL CONNECTOR
HORIZONTAL CONNECTOR
14 IN. / 355 MM
12 IN. / 305 MM
12 IN. / 305 MM
13 IN. / 330 MM
7 IN. / 178 MM
10 IN. / 254 MM
3 IN. / 76 MM
23 IN. / 585 MM 20.5 IN. / 521 MM 20.5 IN. / 521 MM 20.5 IN. / 521 MM 20.5 IN. / 521 MM
16 IN. / 406 MM
9.5 IN. / 241 MM
9.5 IN. / 241 MM 13.5 IN. / 343 MM 14.5 IN. / 370 MM
19 IN. / 483 MM
11.5 IN. / 292 MM
11.5 IN. / 292 MM
BACK I
H
H
A
HEATER
D
G
FRONT
CAUTION
J
F
M
2009
2010
MADE IN CANADA
5050.73
DO NOT REMOVE THIS LABEL
WH-
PACIFIC VISTA
VISTA CLASSIC
MODEL:
ALDERLEA T4
* ALCOVE
MOBILE HOME
INSTALLATION
INSTALLATION
USING
USING
DOUBLE WALL
DOUBLE WALL
CONNECTOR
CONNECTOR
12 IN. / 305 MM
12 IN. / 305 MM
7 IN. / 178 MM
11 IN. / 279 MM
12 IN. / 305 MM
3 IN. / 76 MM
N/A
8 IN. / 203 MM
N/A 16.5 IN. / 419 MM
BACK WALL
ADJACENT WALL
C
B
E
F
MANUFACTURED BY:
PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
2975 ALLENBY RD., DUNCAN, BC V9L 6V8
DATE OF MANUFACTURE
A
M J
J
A S O N D
2011
2012
2013 2014
VST1-C-1a