Fuse capacity: 16A
Note:
Check on the rating plate the value for the
total connection power for establishing the
fuse power.
In case of a direct connection to the mains
you have to interpose an omnipolar switch a
minimum opening between contacts of 3
mm.
The yellow-green grounding cable has not
to be interrupted by the switch.
The supply cord must be positioned in such
a way as it does not reach in any point a
temperature higher by 50˚C than the room
temperature.
Before connecting check that:
•
fuse and household electric installation
can bear the charge of the appliance
(see rating plate);
•
The socket or the omnipolar switch used
for connection is easily reachable when
the appliance is installed.
How to proceed?
•
Unscrew and remove the protective
cover at the back of the appliance;
•
Connect the power cord to the terminal
of the cooker according to the table
no.1;
•
Fix by means of cable clamp;
•
Make sure that the connection to the
terminal is matching the network power;
•
Remount and screw the protective cover
at the back of the appliance.