ARO 66610X-X-C Series Operator's Manual - Page 8
Browse online or download pdf Operator's Manual for Water Pump ARO 66610X-X-C Series. ARO 66610X-X-C Series 8 pages. 1” diaphragm pump
Product discharged from exhaust outlet.
y
Check for diaphragm rupture.
y
Check tightness of diaphragm nut.
Air bubbles in product discharge.
y
Check connections of suction plumbing.
y
Check "O" rings between intake manifold and fluid caps.
y
Check tightness of diaphragm nut.
8"
12-1/2"
(318 mm)
6-1/4"
7-5/16"
Page 8 of 8
TROUBLE SHOOTING
DIMENSIONAL DATA
(Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).
1- 11 1/2 NPTF -1 (66610X, 66611X)
Rp 1 (1 - 11 BSP parallel) (66612X, 66613X)
(203 mm)
1-1/4"
(32 mm)
(159 mm)
( 186 mm)
1- 11 1/2 NPTF -1 (66610X, 66611X)
Rp 1 (1 - 11 BSP parallel) (66612X, 66613X)
Low output volume, erratic flow, or no flow.
y
Check air supply.
y
Check for plugged outlet hose.
y
Check for kinked (restrictive) outlet material hose.
y
Check for kinked (restrictive) or collapsed inlet
material hose.
y
Check for pump cavitation − suction pipe should be sized
at least as large as the inlet thread diameter of the pump
for proper flow if high viscosity fluids are being pumped.
Suction hose must be a non-collapsing type, capable of
pulling a high vacuum.
y
Check all joints on the inlet manifolds and suction con-
nections. These must be air tight.
y
Inspect the pump for solid objects lodged in the dia-
phragm chamber or the seat area.
Outlet
11-9/16"
(294 mm)
Inlet
4"
(102 mm)
13/32" Slot
Figure 5
8-9/16"
(217.5 mm)
Air Inlet
1/4 - 18 NPTF -1
6-1/2"
(165 mm)
(10 mm)
PN 97999-100
66610X-X-C