abc Fleck 5600SXT Manual - Page 9

Browse online or download pdf Manual for Water Dispenser abc Fleck 5600SXT. abc Fleck 5600SXT 13 pages. Water softener with upflow carbon tank

abc Fleck 5600SXT Manual

Attach Tank Lines

Step 6 – Attach Drain Line to Fleck Meter
Step 7 – Connect Brine Line to Fleck Meter
Step 8 – Connect Brine Well to Tank Side Wall
1. Wrap threaded connection point with 3-4
wraps of Teflon tape. Install provided plastic
barbed fitting.
2. Install drain line (not included) to barbed
fitting (found on Fleck valve) with a stainless
hose clamp (not included). Drain line should
extend to a main drain to dispose of waste
water.
1. Prep brine line prior to install using brass
nut, plastic Ferrule & brass tube insert.
2. Connect provided brass nut to the Fleck
valve. Be careful not to overtighten. Over-
tightening will cause damage.
1. Locate predrilled hole in brine tank. Fas-
ten brine well to side wall of brine tank using
the white overflow elbow & plastic nut.
* This is preinstalled on Space Saver version.