INSTALLATION
STEP 1 - INSTALLING THE EZFILL™ SOAP DISPENSING SYSTEM SOAP DISPENSER
Drill a hole in the counter top at the
designated location.
Remove and retain the basin nut and
1
the gasket from the base of the soap
dispenser body, sliding completely
over and off the soap tube, Com and
Power Cables.
Place the soap dispenser shank through
the escutcheon flange (with O-ring
down) into the hole in the counter top.
2
Slide the gasket, disk and nut over the
black soap tube and both cables and
thread onto the shank and secure it to
deck underside.
Black Nylon 1/4" dia. (Ø6) tube 36" (914)
long is supplied permanently attached
to dispenser head.
Assemble the tube to the connector
3
on pump by pushing it on(provided on
end of black tube).
Plug the Com cable into the Socket
cable (See Step 8)
Fix the pump to the desired location by
securing the support with the supplied
screws.
4
For ease of installation preference,
optionally swap steps 3 and 4 while
ensuring pump is within reach range of
Com cable.
1408201234 Rev J
MAX 1-3/16"
(Ø30)
MIN 1-1/32"
(Ø26)
1-1/8" Dia (Ø28)Recommended hole size
36" (914)
36" (914)
tube length
tube length
6
05 August 2015