PODIUM MOUNTED AUTOMATIC GEL HAND SANITIZER DISPENSER (HSD) INSTALLATION GUIDE (Pg 3 of 4)
6. Remove the protective sticker covering the sensor. (see Fig. 6)
7. Fill the 1.6 Gal [6 L] tank with Gel Sanitizer in a viscosity range of 3.5k – 6.5k cP (mPa•s) and a pH in range of 7
± 1.5.
8. Push-button on pump motor runs pump continuously to prime Gel in tubes until Sanitizer is dispensed from the
spout.
OPERATION
System shall operate each time an object is positioned within the sensing range of 1-3/16" to 3-15/16" ± 3/8" (30
to 100 ± 10) directly in front of the spout of the dispenser. A stream of appropriate viscosity nonabrasive Gel
Sanitizer drops with total dispense amount of 0.03 oz (0.8 ml) will be pumped from the nozzle during each
activation. LED will display blue flash for sensing and continuous flashing for low battery condition.
BATTERY MODE ONLY:
When the batteries weaken, the red indicator light will blink at a constant rate when the user's hands are within the
sensor range. The batteries should be replaced within two weeks.
To replace the batteries (same as Step 5. above):
1. Carefully open the battery box, use Phillips drive #2 to remove cover screws.
2. Remove the old batteries from carrier tray.
3. Replace the used batteries with new 'D' batteries in same polarity.
4. Close the box and re-tighten the screws and reconnect battery cable.
NOTE: Do not mix used batteries with new ones
MAINTENANCE
Care and cleaning of chrome and special finishes- see also PCM document.
DO NOT use steel wool or cleansing agents containing acids, bleach, chlorine, ammonia, abrasives, or the like. Use of
any cleaning or maintenance products containing these substances may damage the surface of the dispenser. For
surface cleaning use ONLY soap and water, then wipe dry with a clean cloth or towel.