ASL INTERCOM PS 285 Gebruikershandleiding - Pagina 5

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} ASL INTERCOM PS 285. ASL INTERCOM PS 285 8 pagina's. Dual channel booster power supply
Ook voor ASL INTERCOM PS 285: Gebruikershandleiding (12 pagina's)

4.0

MECHANICAL INSTALLATION

For this unit a vertical rack space of 1RU (44,5
mm) is required. It is not necessary to provide rear
support by extra bracing or shelving.
Adequate ventilation must be provided by allowing
sufficient space around the sides and rear of the
unit to ensure free circulation of air.
5.0

FRONT PANEL CONTROLS

1
POWER ON/OFF push button
To switch mains power on or off
2
OVERLOAD LED
This red LED illuminates if the circuit breaker
shuts off line power due to overload.
A cause for overload can be too many user
stations connected or a short circuit in the
interconnecting cables.
The circuit breaker resets automatically 3
seconds after the cause of the overload has been
removed and restores the line power, provided
the PS 285 is not in standby mode. During short
circuit, the LED flashes every 3 seconds.
6.0

REAR PANEL CONNECTORS

5
DC INPUT connectors
These connectors accept 24 – 30 V DC as a
back-up power source should mains fail or not be
available
6
INTERCOM LINE INPUT connectors
These XLR-3 connectors are the sense inputs
and should be connected to the intercom lines
coming from a PS 289 separate power supply or
from a PS 279 master station (a connector for
channel A and a connector for channel B)
Pin assignments:
pin 1: 0V / ground shield
pin 2: +30V power wire
pin 3: audio wire
PAGE 5
User Manual PS 285 / October 2013 © ASL Intercom BV
Forced cooling is not required.
The power supply regulator is mounted on the
bottom of the PS 285. After a period of time it will
feel hot to the touch on top and bottom.
This is normal and should be no cause for alarm.
3
"ON" LED (one for each channel)
This yellow LED illuminates if line power is
detected at the intercom line input connector.
The standby mode (see #4) is abolished and the
referring channel of PS 285 is now supplying 30V
DC line power to its connected user stations.
4
STANDBY LED (one for each channel)
This green LED is lit if no line power is detected
at the intercom line input connectors.
The referring channel of the PS 285 is now in
standby mode
7
INTERCOM LINE OUTPUT connectors
Provided line power is detected at the XLR-3
input connectors (#6), 30V DC line power is
supplied to the user stations which are connected
to these XLR-3 output connectors via standard
microphone cable. There are 2 connectors for
channel A and 2 connectors for channel B.
Pin assignment: same as the input connectors
8
FUSE holder
A fuse protects the PS 285 against severe
internal damage in case of malfunction of the
power section. Before replacing the fuse the
mains cord must be removed.
9
MAINS INLET
IEC Mains connector.