RAVE II STAIR LIFT: SECTION 5
TROUBLESHOOTING
SECTION 5
TROUBLESHOOTING
If the lift does not operate, diagnose the problem listening to the beeps emitted.
MAJOR FAULTS
Runaway
No Power
Conflicting switches FOOTREST UP and FOOTREST DOWN
Conflicting switches OBSTRUCTION UP and OBSTRUCTION DOWN
Conflicting switches FOOTREST DOWN and OBSTRUCTION UP
Conflicting switches FOOTREST UP and OBSTRUCTION DOWN
Conflicting switches STOP UP and STOP DOWN switches both detected
Conflicting switches STOP UP and STOP DOWN switches both NOT detected
MINOR FAULTS
Single long beep. Will reset once fault is cleared.
Seat swiveled out of position
•
Edge safety detected
•
Footrest
•
Current overload condition
•
A low battery voltage condition
•
RAVE II STAIR LIFT:
12
04DEC2020 | 610-00052 REV F
Owner's Manual
MANUAL OVERRIDE
OPERATION
If your lift fails to operate and the operator is unable
to exit the lift on the stairway, another person may
use the optional manual override tool to lower or
raise the lift to a landing. However, please follow the
instructions on the bottom safety flap of the lift and
turn the "On/Off" switch to "Off". Insert the manual
override tool into the hole in the lower safety flap
until it engages the motor shaft, then turn in the
direction desired.
WARNING
!
Do not operate the lift with the manual override
tool engaged.
Number of Beeps
1
2
3
4
5
6
7
8