Caution: This page is only valid for transformers that contain these exact color codes for the primary winding. Early
production units did not contain a multiple tap transformer. If the terminal strip has all these color coded wires, then the
unit has the multiple tap transformer.
FILAMENT/BLOWER WIRING INSTRUCTIONS
The AL-1500 and 1500(X) amplifiers come prewired for 240V line voltage and with the blower prewired for medium
high fan speed. NOTE: The AL-1500J Japanese export model is prewired for 208V line voltage. This page gives filament
transformer connection details for various line voltages and blower speeds. The five lug terminal strip and the single lug
terminal strip are located immediatgly behind the ON/OFF rocker switch inside the unit. The drawing below shows the
connection of transformer leads and their purpose.
This chart shows the color code of the transformer leads and their purpose. The number in paren-
thesis indicates the number of the terminal lug that the transformer lead is connected to. The
number three (3) lug is not used to change the filament or blower wiring. Do not add or remove any
wires from the number three (3) lug. Refer to the drawing above. Use the lug numbers above when
referring to both of the Filament connection chart and the Blower connection chart below.
FILAMENT TRANSFORMER LINE VOLTAGE T
are two wires that connect to the terminal lugs which
determine the Filament Line Voltage. The BLACK wire
from the power switch and WHITE wire from rear of the
unit connect to different terminal lugs depending on the
voltage desired. The AL-1500 and 1500(X) come prewired
for 240V operation*. AL-1500J comes prewired for 200V
operation**. Refer to the chart below. The voltage listed in
the chart below is the maximum line voltage that should be
applied to a given tap. Operation with line voltage in
excess of 'he tan voltage selected can result in a reduction
of tube life
h
ere
BLOWER CONNECTIONS
The GREEN and WHITE wires from the rear of the unit
connect to the terminal lugs to control the air speed of the
fan. The AL-1500/X/J are prewired for the medium high
speed setting*. Refer to the char below. The blower
connections can be moved to lower speed taps if air noise
is excessive. Ameritron recommends using the highest
speed tap that noise considerations permit. The lowest
speed tap will develop sufficient air flow for standard
amateur SSB and CW full power operation. The highest
speed taps should be used for contest or RTTY operation.