4.2 Using an alternative Power Supply Unit
If you do not have a TRACO Power Supply Unit, you can use a 24 V DC supply to power
the NIR-656 / NIR-2K Thermal Imager.
You will need to connect the camera to the power supply via a cable, available from
AMETEK Land:
Two lengths of cable are available:
Length: 20 m / 66 ft, Part Nº 814614
Length: 50 m / 164 ft, Part Nº 814615
Minimum bend radius: 50 mm / 2 in
Recommended mounting method: Cable fixings/Conduit (Insulate as necessary)
IP Rating: IP65
Cable connections:
Black - connect to + 24 Volts
White - connect to 0 Volts
12
Fig. 4-6
6)
Strip back the mains cable wires to
the appropriate lengths and connect
them to the Input connector terminals
(Fig. 4-5) as per the wiring schedule
below:
Pin 1 = Live
Pin 2 = Neutral
Pin 3 = N/C
E = Earth
7)
The mains input cable connector is now
ready for re-assembly and connection
to the Power Supply Unit (Fig. 4-6).
Reassemble the mains input connector.
8)
Attach the mains cable to the Input
connector of the Power Supply Unit
(Fig. 4-7).
You can now connect the TRACO Power
Supply Unit to the NIR-656 / NIR-2K
Thermal Imager camera via the pre-
wired power cable assemblies.
NIR-656 / NIR-2K
Installation Guide