Figure 8- Options tab
Configuration – here you can load, save, reset or purge the INDI driver configuration.
PWM cycle – that is the time in milliseconds that cycles regulated PWM outputs power.
Relay labels – these are names of the outputs, that are shown for convenience in the Output tab.
Step delay – time in milliseconds of each focusing motor step. Should be adjusted to the focusing
motor parameters and selected resolution.
Snoop device – that is telescope device name that will be used to retrieve aperture and focal length
data.
Max travel – that is the maximum output position of the focuser. This value is used to calculate the
step size.
Resolution – here required focusing motor resolution can be selected. For unipolar geared motors
1/1 to 1/4 resolution is recommended. For bipolar motors, without an additional gearbox 1/16 or
1/32 is recommended.
Hold power – here you select the holding power of the focusing motor. For unipolar motors, it should
be set to 0 to avoid motor overheating. For bipolar stepper motors should be set to some significant
value, so the balance between the motor temperature on idle and holding torque will be preserved.
Recommended values are 40-60%.