Astronergy CHSM60M-HC Installatiehandleiding - Pagina 11
Blader online of download pdf Installatiehandleiding voor {categorie_naam} Astronergy CHSM60M-HC. Astronergy CHSM60M-HC 12 pagina's. Crystalline silicon pv
Ook voor Astronergy CHSM60M-HC: Installatiehandleiding (12 pagina's), Installatiehandleiding (12 pagina's), Installatiehandleiding (18 pagina's), Installatiehandleiding (19 pagina's), Handmatig (19 pagina's)

The tightening torque should be 210±20 N•cm.
4.2.6 Approve the use of UL-467 certified bonding and grounding devices, including Burndy
(formerly Wiley Electronics) Washer Electrical Equipment Bonding (WEEB) and similar
devices, such as barbed washers, that meet the requirements of UL-467 as suitable for
electrical bonding and grounding PV modules to PV mounting systems.
4.2.7 Other grounding methods may be allowable when tested with the racking system per
UL 2703 requirements.
5 Maintenance
5.1 Regularly carry out a visual inspection for dirt, dust, bird dropping, leaves, and other detritus
covering the modules.
5.2 If snow is present, a soft-bristled brush with soft bristles may be used to clean the surface of
the modules.
5.3
Regular electrical and mechanical inspection by a licensed professional will keep the
system safe and operating at maximum efficiency.
5.4 Recommended PV module Clean-up period
To get high output performance, PV module needs to be cleaned-up periodically as below:
① Normal: Minimum one time per every month; Dust weather: Right away after the dust
wind;
② The period of the PV module cleaning shall be determined by the condition of the
weather & pollution. O&M operator shall keep a record of weather condition everyday with
data.
5.5 Condition of Cleaning
5.5.1 Use clean water or filtered water with soft type material (a sponge) to wipe the PV
module. Never use chemicals on the surface of the module.
5.5.2 Cleaning after sunset or before sunrise is recommended for safety of O&M operator
shock from heat stroke.
5.5.3 Do not use abrasive powder, abrasive cleaners, scrubber cleaners, polishers, sodium
hydroxide, benzene, nitro-thinners, acid or alkali and other chemical substances.
Do not clean broken glass or modules with broken lines or exposed wires, as it may
5.5.4
cause the electric shock.
Chint Solar (Zhejiang) Co.,Ltd. | Add:1335 Bin´an Road, Binjiang District, Hangzhou | P.C: 310053
Tel: 0086-571-5603 1888 | Fax: 086-571-5603 2316 | Website: http://energy.chint.com/