Air King 3C614C/9166C Gebruiksaanwijzing & onderdelenhandleiding

Blader online of download pdf Gebruiksaanwijzing & onderdelenhandleiding voor {categorie_naam} Air King 3C614C/9166C. Air King 3C614C/9166C 2 pagina's. 20" whole house window fan

Air King 3C614C/9166C Gebruiksaanwijzing & onderdelenhandleiding
MODELO 3C614C/9166C
MÉTODO B
(POR ADENTRO DE LAS MOLDURAS)
1. Marque la posición de los
1/8" (3,2 mm)
agujeros para los Tornillos en
los bordes interiores del marco
de la ventana utilizando el Patrón
suministrado. (Figura 2)
2. Instale los 4 Tornillos en el
marco. NO LOS APRIETE DEL
TODO. Deje 1/8" (3,2 mm) entre
la superficie del marco y la
Cabeza de los Tornillos.
3. Afloje los 4 Tornillos para Paneles
de Extensión (Figura 1) y
extienda los Paneles Laterales
Figura 2
hasta que el Ventilador quede
bien ajustado entre los lados del
marco de la ventana.
10
8
9
33
5
3
4
10
6
7
36
2
35
1
34
36
36
LISTA DE PIEZAS DE REPUESTO
No.
Parte No.
Descripción
1
2070024G
Emblema AirKing
2
2010208
Protector del Ornamento
3
2096151
Rejilla Interior
4
2091121
Tornillo Prisionero
5
2011219
Hélice
6
2030073A
Conjunto del Motor
7
3091118
Arandela #8
8
2091413
Tornillo para Madera #8 x 3/4"
9
2060085
Paneles Laterales
10
2090039
Tornillo #8 x 3/8" (Tipo 25)
11
2010720
Cuerpo del Ventilador con Canales
12
2011224
Rejilla Exterior
13
2090548
Atadura para Cable #10
14
3091135
Tornillo #10 x 1/2"
15
2090289
Capacitor
16
2011225
Cubierta del Motor
17
2090008
Tornillo #8 x 1/2" (Tipo 25)
18
3091815
Conector Eléctrico
Rev. D 1/00
4. Instale el Ventilador en la ventana
enganchando las Ranuras en los Tornillos
en el marco de la ventana. Deslice el
Ventilador hacia abajo en los Tornillos
hasta que descanse sobre la parte inferior
del marco. (Figura 3)
5. Apriete los Tornillos para Paneles de
Extensión para asegurario en esa posición.
OPERACIÓN
Este Ventilador AirKing para Toda la Casa tiene un duradero motor
eléctrico reversible de 3 velocidades con arranque por capacitor. Tiene
tres velocidades: Alta (Hi), Media (Medium) y Baja (Low) tanto para uso
de Ventilador como de extactor. El interuptor de control está
convenientemente ubicado en la parte inferior derecha del cuerpo del
Ventilador. Ajuste la Perilla a la dirección y Velocidad deseadas.
16
14
15
12
13
11
22
23
19
7
22
26
10
24
23
25
26
18
29
33
10
30
27
28
32
31
Cant.
No.
Parte No.
Descripción
1
19
7092211
Tuerca Hexagonal #8 - 32
1
20
2010744
Cubierta del Interruptor
1
21
2055052
Interruptor Reversible de 3 Velocidades
1
22
2091133
Tuerca Hexagonal 1/4" - 20
1
23
2090053
Arandela de Presión 1/4"
1
24
2090566
Atadura para Cables
8
25
2090044
Tornillo 6 - 32 x 1/4"
4
26
2090509
Canal de Goma
2
27
3091303W
Buje para el Alambre
4
28
2050009AW
Cable de Alimentación
1
29
2046101
Alambre de Conducir Verde
1
30
2046922
Alambre de Conducir Azul
1
31
2084071
Plantilla
1
32
2065228A
Placa del Interruptor
1
33
2091130
Tornillo 1/4" - 20 x 1"
1
34
2010745
Perilla del Interruptor
5
35
2090547
Tuerca de Lámina
4
36
2090062
Tornillo #8 x 1/2" (Punta A)
4
OPERATING INSTRUCTIONS & PARTS MANUAL
Tornillo
Ranura
Figura 3
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
DESCRIPTION
The AirKing 20" (50.8 cm) Whole House Window Fan features three
17
intake and three exhaust speeds. Fan will fit windows 27" (68.6 cm) to
38" (96.5 cm) wide x 26-1/4" (67.3 cm) high. The adjustable side panels
are designed to accommodate Fan mounting either inside or outside
interior window trim. The 3-paddle Fan blade is driven by a permanently
pre-lubricated permanent split capacitor motor with 6' (1.8 m), 18/3 cord set.
18
SPECIFICATIONS
17
Motor ....................................... 120V, 50/60 Hz
Blade diameter ....................... 20" (50.8 cm)
Speeds .................................... 3 Intake, 3 Exhaust
Control .................................... Rotary Switch
20
Approvals ................................ UL Listed. Close mesh Fan guard
21
MODEL
SPEED
CFM
M
3
/s
RPM
Amps
Watts
9
dB A
8
GENERAL SAFETY INFORMATION
1. Make certain that the power source conforms to the electrical
requirements of the Fan.
2. The power cord is equipped with a three-prong grounded plug that
must be inserted into a matching receptacle. Under no circumstances
must the grounding prong be cut off the plug. Where a two-prong wall
receptacle is encountered, it must be replaced with a properly grounded
three-prong receptacle installed in accordance with the National
Cant.
Electrical Code (NEC) and all applicable local codes and ordinances.
4
This work must be done only by a qualified electrician, using copper
1
wire only.
1
WARNING: USE OF A THREE-PRONG TO TWO-PRONG ADAPTER IS
4
NOT RECOMMENDED. IMPROPER CONNECTION MAY CREATE
4
THE RISK OF ELECTROCUTION. USE OF SUCH ADAPTERS IS NOT
2
PERMITTED IN CANADA.
1
3. Where possible, avoid the use of extension cords. If they must be
4
used, minimize the risk of overheating by ensuring that they are UL
1
listed and of the proper gage and length. Never use a single extension
1
cord to operate more than one Fan.
1
4. Do not insert fingers or foreign objects into the Fan. Do not block or
1
tamper with the Fan in any manner while it is in operation. Do not touch
1
the Fan while in operation or just after it has been turned off, as some
1
parts may be hot enough to cause injury.
4
5. Unplug power cord before installing or servicing the Fan.
1
WARNING: DO NOT DEPEND UPON THE ON-OFF SWITCH AS THE
3
SOLE MEANS OF DISCONNECTING POWER WHEN INSTALLING OR
6
SERVICING THE FAN. ALWAYS UNPLUG THE POWER CORD.
2085109A
Rev. D 1/00
20" WHOLE HOUSE WINDOW FAN
20" (50.8 cm) MODEL 3C614C/9166C
READ AND SAVE THESE INSTRUCTIONS
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
6. This Fan is intended for general use ONLY. It must NOT be used in
potentially dangerous locations such as flammable, explosive, chemi-
cal-laden or wet atmospheres.
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL
DEVICE.
MAINTENANCE
WARNING: ALWAYS UNPLUG THE CORD BEFORE SERVICING.
CLEANING: Use a soft cloth and a mild soap solution such as liquid dish
washing detergent.
CAUTION: Do not use gasoline, benzine, thinner, harsh cleaners,
etc. which will damage the Fan.
Dry all parts with a soft cloth completely before reconnecting to power supply.
meets OSHA requirements.
STORAGE: When not in use, keep unit in a clean dry place.
MOTOR IS PERMANENTLY LUBRICATED.
3C614C/9166C
HIGH
MED
LOW
ASSEMBLY AND INSTALLATION
7005
6165
4160
PLEASE REMOVE CORRUGATED PACKING RING BETWEEN FAN
3.31
2.91
1.96
BLADE AND GRILL BEFORE INSTALLATION AND OPERATION OF
834
700
520
FAN.
3.20
2.40
1.80
The large number of window styles and types makes it impossible to
364
280
185
describe one universal installation procedure.
64
59
50
The methods outlined below are recommended as being well-suited for
most common styles of double-hung windows. Whichever method you
choose should allow the window to be closed easily for security and
protection of home furnishings against the weather. Refer to illustrations
while following METHOD A (OUTSIDE of TRIM) or METHOD B (INSIDE
of TRIM) below.
Tools Required: Screwdrivers
Hardware Provided: Four #8 x 3/4" Slotted Head Screws
METHOD A
1. Loosen 4 Extender Panel Screws and extend Side Panels to clear the
outer edge of trim on each side of window. (Figure 1)
Flange
2. Rest Fan on window sill with Flange on Side Panels over trim. Push in
Side Panels tight against outer edge of trim. With Side Panel in position,
mark Screw locations at top of Slot and drive in the Wood Screws
(provided) until tight.
3. Retighten Extender Panel Screws to complete installation.
1
(OUTSIDE OF TRIM)
Extender
Panel
Slots
Screws
Figure 1
2085109A