Technical data
Electrical Data
Operating voltage Ub
Short-circuit proof
Operating current without load
Initializing time
Sensing principle
Fieldbus interface
Data rate (fieldbus)
User address
Steps per turn
Number of turns
Incremental output
Interference immunity
Interference emission
Programming interface
Programmable parameters
Diagnostic functions
LED status indicator
Approvals
Electrical data (Speed switch)
Switching accuracy
Switching outputs
Output switching performance
Switching delay
Mechanical
Dimensions (flange)
Shaft type
Flange
Protection class DIN EN 60529
Operating speed
Switching speed range
Operating torque typically.
36
Operating Manual
PMG10
10-30 V DC (Ub (Bus))
4,75-30 V DC (Ub (Ink))
Yes
≤ 200 mA
≤ 500 ms after switch-on
Magnetic
Profibus DPV0/V2
9,6-12000 kBaud
Rotary switch inside the bus terminal box
8192 / 13 Bit
65536 / 16 Bit
Rectangle TTL/HTL, TTL/RS422
see data sheet and declaration of conformity
see data sheet and declaration of conformity
I
RS485 (≤ 600 m)
Bus system (see reference at the end of the
chapter)
Additional output (ppr number)
I
Switch off / on speed
Position and parameter errors
DUO LED inside the bus terminal box
4 LEDs at rear of the device
see data sheet and declaration of conformity
±2 % (or 1 digit)
1 output
II
(Open-collector
or semiconductor relay
30 V DC; ≤ 100 mA
≤ 20 ms
ø 115 mm
ø 11 mm solid shaft
EURO flange B10
IP66/IP67
≤6000 rpm
ns (off) = ±2 ... ±6000 rpm,
(PMG10P: factory setting 6000 rpm)
10 Ncm
PMG10 & PMG10P Profibus DP | V1
Baumer Hübner
I
II
)